stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

900 HOE AVENUE

Bronx · ZIP 10459 · BIN 2006072 · Longwood · Last violation Jun 11, 2026 · Last complaint Jun 18, 2026

NeighborhoodLongwood
More violations than 98.6% of nearby buildings
More violations than 99% of buildings and more complaints than 96% of buildings in Longwood. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 850 violations · 461 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
38 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous38Class Bhazardous51
Housing Preservation & Development Violations
Total violations since 2008
3,080
162 per year avg.↑ Up 143% in the last 2 years (850 vs 350 prior 2 yrs)
Open violations
105
Class C (immed. haz.)ⓘ38
Class B (hazardous)ⓘ51
Rent-impairingⓘ3
Housing Preservation & Development Complaints
Total complaints since 2003
3,396
142 per year avg.↑ Up 225% in the last 2 years (461 vs 142 prior 2 yrs)
Complaint Resolution
No access20%Violation issued32%No violation35%Phone resolved13%Other0%(3,396)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ510 violations
Extermination & Rodent Eradicationⓘ152 violations
Egressⓘ139 violations
Paintingⓘ104 violations
Lead-Based Paintⓘ99 violations
Water Supplyⓘ93 violations
Cleaningⓘ54 violations
Smoke Detecting Devicesⓘ36 violations
Top complaint groupsⓘ
5 yrsAll time
Bldg maintenanceⓘ169 complaints
Mold & pestsⓘ127 complaints
Water & plumbingⓘ116 complaints
Heat / hot waterⓘ97 complaints
Electricalⓘ36 complaints
Appliancesⓘ30 complaints
Safety & fireⓘ25 complaints
Elevatorⓘ1 complaints
Outdoor / structuralⓘ1 complaints
Adminⓘ1 complaints
Hide violations ↑See complaints →

Violation log

3,080 violations

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Open violation ages
▪ < 30 days19% (20)
▪ 30–90 days52% (55)
▪ 3–12 months21% (22)
▪ 1–3 years4% (4)
▪ 3+ years4% (4)
Prior 4 yr.
Immed. Emergency6%5%
Emergency51%55%
Non-Emergency43%40%
(289)
(418)
Issued
Description
Class CClosed—Aug 2, 2018INSTALL/REPLACE/REPAIR WINDOW GUARDS (PUBLIC AREA) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. AT PUBLIC HALL, SECTION ''NORTH''
Class BClosed—Aug 2, 2018RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER WINDOW SASH SPRING BALANCE AT PUBLIC HALL, SECTION ''NORTH''
Class CClosed—Aug 2, 2018REPAIR BROKEN PAYING · PAVING AND GRADING§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT FRONT INNER COURT YARD OF BUILDING
Class BClosed4LJul 31, 2018PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES IN ROOMS EAST 1, EAST 4 AND THE BATHROOM. LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed—Jul 26, 2018REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR FROM STREET TO PUBLIC HALL , 1st STORY
Class BClosed3AJul 23, 2018REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed3AJul 23, 2018REFIT DOORS ETC. · EGRESS§ 27-2005 ADM CODE REFIT LOWER SASH GLASS WINDOW IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed3AJul 23, 2018REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed3AJul 23, 2018REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed3AJul 23, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed3AJul 23, 2018REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING ELECTRICAL LIGHT FIXTURE IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed3AJul 23, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed3AJul 23, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed3AJul 23, 2018REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD DOOR AT ENTRANCE IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed2EJul 19, 2018ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CRACKED VINYL FLOOR TILES CREATING A TRIP HAZARD IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class BClosed2EJul 17, 2018ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNSECURED AIR CONDITIONER AT WINDOW AT ROOM EAST 1AND EAST 2 LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class BClosed2EJul 17, 2018REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). IMPROPERLY INSTALLED AT WALL LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class BClosed2EJul 17, 2018REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR IMPROPERLY INSTALLED AT WALL LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class BClosed2EJul 17, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
Class AClosed—Jul 6, 2018TELEVISION OR RADIO ANTENNA · MISCELLANEOUS§ 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE AT 5TH STORY SOUTH BALCONY AT WEST AT BUILDING FRONT AT FIRE ESCAPE
Class AClosed—Jul 6, 2018POST SMOKE DETECTOR NOTICE · POSTING/SIGNAGE§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING INFORMATION AT PUBLIC HALL, 1st STORY
Class AClosed—Jul 6, 2018POST CO DETECTOR NOTICE · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
Class AClosed—Jul 6, 2018POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
Class BClosed—Jul 6, 2018REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ITEMS AT 3RD STORY BALCONY AT WEST AT BUILDING FRONT AT FIRE ESCAPE
Class BClosed2EJul 6, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH AND SOUTH WALLS IN THE 1st BEDROOM FROM EAST LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class CClosed—Jun 18, 2018RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT LOWER SASH WINDOW AT PUBLIC HALL, 1st STORY
Class BClosed—Jun 18, 2018REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DECORATIVE MARBLE SLOB AT DOOR WAY LEADING FROM LOBBY TO THE NORTH SECTION OF THE BLDG. AT PUBLIC HALL, 1st STORY
Class BClosed4GJun 18, 2018REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class AClosed—Jun 18, 2018POST GAS LEAK NOTICE · POSTING/SIGNAGE§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED
Class CClosed—Jun 18, 2018RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH GLASS AT LOBBY NORTH WINDOW AT PUBLIC HALL, 1st STORY
Class CClosed—Jun 18, 2018RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH WINDOW GLASS AT INTERMEDIATE LANDING OF PUBLIC HALL STAIR BLDG. NORTH SECTION AT PUBLIC HALL STAIRS, 1st STORY, SECTION ''NORTH''
Class CClosed—Jun 18, 2018RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH WINDOW GLASS AT INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 2nd STORY, SECTION ''NORTH''
Class CClosed2FJun 13, 2018INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 2; IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed2FJun 13, 2018MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed2EMay 14, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed2EMay 14, 2018REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed2EMay 14, 2018REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class AClosed4FMay 3, 2018REFIT DOORS ETC. · EGRESS§ 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class AClosed4FMay 3, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed4FMay 3, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed4FMay 3, 2018REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed4FMay 3, 2018TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROX 20 SQUARE FEET AT CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed4FMay 3, 2018REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed4FMay 3, 2018REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed4FMay 3, 2018RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR FRAME IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed4GMay 3, 2018REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AND ASSEMBLY IN THE ENTRANCE LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class CClosed4GMay 3, 2018ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BClosed4GMay 3, 2018REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BClosed4GMay 3, 2018REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BClosed4GMay 3, 2018REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class CClosed
Aug 2, 2018
INSTALL/REPLACE/REPAIR WINDOW GUARDS (PUBLIC AREA) · WINDOW GUARDS
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. AT PUBLIC HALL, SECTION ''NORTH''
Class BClosed
Aug 2, 2018
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER WINDOW SASH SPRING BALANCE AT PUBLIC HALL, SECTION ''NORTH''
Class CClosed
Aug 2, 2018
REPAIR BROKEN PAYING · PAVING AND GRADING
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT FRONT INNER COURT YARD OF BUILDING
Class BClosed
Jul 31, 2018Apt 4L
PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES IN ROOMS EAST 1, EAST 4 AND THE BATHROOM. LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed
Jul 26, 2018
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR FROM STREET TO PUBLIC HALL , 1st STORY
Class BClosed
Jul 23, 2018Apt 3A
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class AClosed
Jul 23, 2018Apt 3A
REFIT DOORS ETC. · EGRESS
§ 27-2005 ADM CODE REFIT LOWER SASH GLASS WINDOW IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jul 23, 2018Apt 3A
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jul 23, 2018Apt 3A
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jul 23, 2018Apt 3A
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jul 23, 2018Apt 3A
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING ELECTRICAL LIGHT FIXTURE IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jul 23, 2018Apt 3A
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jul 23, 2018Apt 3A
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jul 23, 2018Apt 3A
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD DOOR AT ENTRANCE IN THE 3rd ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jul 19, 2018Apt 2E
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CRACKED VINYL FLOOR TILES CREATING A TRIP HAZARD IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class BClosed
Jul 17, 2018Apt 2E
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNSECURED AIR CONDITIONER AT WINDOW AT ROOM EAST 1AND EAST 2 LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class BClosed
Jul 17, 2018Apt 2E
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). IMPROPERLY INSTALLED AT WALL LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class BClosed
Jul 17, 2018Apt 2E
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR IMPROPERLY INSTALLED AT WALL LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class BClosed
Jul 17, 2018Apt 2E
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM EAST AT SOUTH , SECTION AT EAST
Class AClosed
Jul 6, 2018
TELEVISION OR RADIO ANTENNA · MISCELLANEOUS
§ 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE AT 5TH STORY SOUTH BALCONY AT WEST AT BUILDING FRONT AT FIRE ESCAPE
Class AClosed
Jul 6, 2018
POST SMOKE DETECTOR NOTICE · POSTING/SIGNAGE
§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING INFORMATION AT PUBLIC HALL, 1st STORY
Class AClosed
Jul 6, 2018
POST CO DETECTOR NOTICE · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
Class AClosed
Jul 6, 2018
POST SIGN INDICATING NAME AND ADDRESS OF JANITOR, ETC. · POSTING/SIGNAGE
§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
Class BClosed
Jul 6, 2018
REMOVE ENCUMBRANCE · EGRESS
§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ITEMS AT 3RD STORY BALCONY AT WEST AT BUILDING FRONT AT FIRE ESCAPE
Class BClosed
Jul 6, 2018Apt 2E
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH AND SOUTH WALLS IN THE 1st BEDROOM FROM EAST LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT EAST
Class CClosed
Jun 18, 2018
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT LOWER SASH WINDOW AT PUBLIC HALL, 1st STORY
Class BClosed
Jun 18, 2018
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DECORATIVE MARBLE SLOB AT DOOR WAY LEADING FROM LOBBY TO THE NORTH SECTION OF THE BLDG. AT PUBLIC HALL, 1st STORY
Class BClosed
Jun 18, 2018Apt 4G
REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS
§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class AClosed
Jun 18, 2018
POST GAS LEAK NOTICE · POSTING/SIGNAGE
§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED
Class CClosed
Jun 18, 2018
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH GLASS AT LOBBY NORTH WINDOW AT PUBLIC HALL, 1st STORY
Class CClosed
Jun 18, 2018
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH WINDOW GLASS AT INTERMEDIATE LANDING OF PUBLIC HALL STAIR BLDG. NORTH SECTION AT PUBLIC HALL STAIRS, 1st STORY, SECTION ''NORTH''
Class CClosed
Jun 18, 2018
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH WINDOW GLASS AT INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 2nd STORY, SECTION ''NORTH''
Class CClosed
Jun 13, 2018Apt 2F
INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 2; IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
Jun 13, 2018Apt 2F
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST
Class BClosed
May 14, 2018Apt 2E
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 5th ROOM FROM EAST LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
May 14, 2018Apt 2E
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
May 14, 2018Apt 2E
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST LOCATED AT APT 2E, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class AClosed
May 3, 2018Apt 4F
REFIT DOORS ETC. · EGRESS
§ 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class AClosed
May 3, 2018Apt 4F
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4F
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4F
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4F
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... APPROX 20 SQUARE FEET AT CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4F
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4F
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4F
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR FRAME IN THE BATHROOM LOCATED AT APT 4F, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4G
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AND ASSEMBLY IN THE ENTRANCE LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class CClosed
May 3, 2018Apt 4G
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4G
REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS
§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4G
REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BClosed
May 3, 2018Apt 4G
REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''