not activeFeb 2, 2021
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 620 eddy street, unit 20.
not activeFeb 2, 2021
building section · repair or replace the kitchen exhaust hood 1001f sfhc
the kitchen exhaust hood is in disrepair. when turned on it makes a threatening screeching sound and struggles to provide draft. repair or replace the exhaust hood.
not activeSep 25, 2020
building section · locate the source of water intrusion and repair 1001f sfhc
there is a leak coming into this unit from above the main entry door. find and fix the source of the leak.
not activeSep 25, 2020
building section · eliminate mold/mildew on walls and ceiling 1301, 1001b11, d, 1306 sfhc
the appearance of the discoloration on the living room walls and ceiling is consistent with mold/mildew. when working on or disturbing this area the presence of mold/mildew should be assumed unless known to be otherwise (as evidenced by an independent mold report) and a qualified mold remediation contractor should employ the appropriate safe work practices. provide containment to the work area using 6 mil visquene. once containment barriers and ground protection are in place, establish a restricted work area to prevent the migration of work debris outside the work area. remove the mold/mildew and all contaminated material in an approved manner from all walls, stud bays and ceiling areas. to insure complete elimination of mold, remove drywall, plaster and insulation 12" past any visible mold. if necessary, drywall, plaster, prep, prime and repaint to provide a durable and cleanable surface. debris shall be double bagged and duct taped and disposed of in an approved manner. mold debris is a toxic hazard that should be secured and contained to minimize potential of migration of this hazard.
not activeSep 25, 2020
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 620 eddy street, unit 1 and the common areas, san francisco, ca.
not activeSep 25, 2020
building section · repair the storage room door and/or hardware 1001l sfhc
in the basement, the storage room door has been torn from its hinges. repair or replace the storage room door.
not activeSep 25, 2020
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeSep 25, 2020
building section · repair walls and ceiling 1001 b13, d, l sfhc
the ceiling in the living room has bubbled and discolored. the wall surface has bubbled and blistered just below. remove damaged or contaminated material. stabilize the remaining material and then plaster, prep, prime and paint to complete the repairs.
not activeSep 25, 2020
fire section · provide smoke detectors 908, 911 sfhc, 907.2.11 sfbc 907.2.11.2
the living room smoke detector in unit 1 was missing. required areas: on the wall or ceiling outside the immediate vicinity of the sleeping areas or bedrooms and in each bedroom. they are also required in each story of a dwelling unit. smoke alarms shall not be installed where ambient conditions such as humidity or temperature would activate them. replace the missing smoke detector.
not activeSep 25, 2020
building section · repair the cast iron waste line 1001f sfhc
in the basement, opposite the electrical meters, there is a 4" cast iron waste line missing a cap. the open line is spitting septic water out onto the floor. cap the open waste line.
not activeFeb 28, 2017
interior surfaces section · eliminate mold/mildew on walls and ceiling 1301, 1001b13, d, 1306 sfhc
the north wall of the master bedroom is covered in mold above the window. the mold pattern continues along the eastern most wall of the same room and its closet and extends into the hallway and kitchen cabinets to the south. eliminate the mold and remove contaminated materials. use mold resistant products to replace them. the water pattern formed in the outside garden area shows that excess water is pooling along the north face of the building. when watering the exterior plants, redirect the waste water so that it moves away from the apartment building walls. the epa has further recommendations for household cleaning and care to minimize the potential for mold growth at the following website: https://www.hud.gov/offices/pih/ih/codetalk/docs/moldprevention.pdf
not activeFeb 28, 2017
interior surfaces section · inspector comments to the resident
as temperatures drop, the air is less able to hold moisture. without good air flow in your home that excess moisture will appear on your walls, ceilings, windows and personal belongings. to increase circulation, open doors between rooms, move furniture away from the walls, open doors to closets and cabinets. open windows in moderate weather, especially while cooking or showering.
not activeFeb 28, 2017
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeFeb 28, 2017
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 620 eddy street, unit 7.
not activeFeb 10, 2017
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 620 eddy street, unit 5 and outside in the light well.
not activeFeb 10, 2017
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeFeb 10, 2017
building section · eliminate mold/mildew 1001b13, d, 1002d, 1301, 1306 sfhc
the water intrusion along this wall has caused a mold issue behind the kitchen cabinets. remove the kitchen cabinets from the wall above the sink and eliminate the mold. remove any contaminated material and replace with new. plaster, prep, prime and paint with a mold inhibitive paint to complete these repairs.
not activeFeb 10, 2017
building section · provide weather proofing on siding (1001(h),703 hc)
the east side of the building is leaking into unit 5. there are a number of imperfections and blisters in the paint on the outside face of the wall. there are also vents above the area leaking. find the source of the leak and conduct repairs to stop water intrusion from making its way into unit 5 at the closet, bedroom, bathroom and kitchen areas.
not activeAug 25, 2015
building section · dbi nov location indicator
this notice of violation also appears as a dbi nov and is identified by the same complaint number 201566672.
not activeAug 25, 2015
plumbing and electrical section · provide plumbing permit 103.1.1 pc
plumbing permits required 103.1.1 upc, 503.0 upc, 301 sfhc you are required to obtain a plumbing permit to correct this violation. when you apply for a plumbing permit, reference the complaint number from this notice of violation. present the signed job card indicating that work is complete to the housing inspector on the date of re-inspection.
not activeAug 25, 2015
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 620 eddy street, in the east light well.
not activeAug 25, 2015
plumbing and electrical section · repair deteriorated drainage pipes at exterior 1001d, f sfhc
while investigating a complaint at this address one of the residents on the east side of the building flushed their toilet and a fine spray emitted from the soil stack on this outside wall. repair or replace the 4" soil stack on the east side of the building.
not activeAug 25, 2015
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeSep 27, 2012
other section · inspector comments
inspector comments regarding "follow up" reinspection: i have scheduled a reinspection of your building on tuesday, 09-october-2012 at 2:00 pm. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owners responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
not activeSep 27, 2012
building section · this notice includes violations for the areas noted.
all common areas of 620 eddy street
not activeSep 27, 2012
other section · repair defective or non-working elevator (1001(l), 713 hc)
repair elevator in order to provide consistent operation for tenants.
not activeNov 30, 2011
building section · this notice includes violations for the areas noted.
all common areas of 620 eddy street and apartment# 24
not activeNov 30, 2011
interior surfaces section · repair or replace non-tamperable temp.-sensing device with a +/- to -1 1/2 degree f. (.8 degrees c.) tol., centrally located in bldg in habitable rm (not mgr or owner's) to which heat is provided, occupied or not (701c hc)
it was noted on november 17, 2011 in apartment# 24 that the thermostat was not functional, repair or replace thermostat.
not activeNov 30, 2011
plumbing and electrical section · other plumbing and/or electrical violations
provide a valid boiler room certificate.
not activeNov 30, 2011
other section · inspector comments
inspector comments regarding "follow up" reinspection: i have scheduled a reinspection of your building on wednesday, 14-december-2011 at 2:00 pm. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owners responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
not activeNov 9, 2011
other section · inspector comments
inspector comments regarding "follow up" reinspection: i have scheduled a reinspection of your building on thursday, 17-november-2011 at 9:15 am. reinspection of premise to include all areas referenced above. please contact inspector galvis to confirm appointment at 415-558-6513. it is the property owners responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. on scheduled reinspection day, provide the inspector with a full access to all common and public areas per attached checklist. your cooperation is appreciated.
not activeNov 9, 2011
building section · this notice includes violations for the areas noted.
620 eddy street apartment #36.
not activeNov 9, 2011
other section · provide heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)
on the day of the reinspection provide access to boiler room and apartment that contains tamper proof thermostat.
not activeJun 5, 2007
building section · note: on reinspection day, property manager, owner or the owner's agent needs to demonstrate the workability of the fire escape ladders. the fire escapes are to be checked on all buildings during the course of a routine inspection. non-working fire escape ladder is a life safety hazard and must be corrected immediately. reminder: test and verify that all windows or doors leading to emergency fire escape are operational and unobstructed. advise tenants not to block the path of emergency exits on the inside.
inspect, service and lubricate fire escape ladder, crank, cable as well all moving parts. 1001hc.
not activeJun 5, 2007
building section · designate apartment number as well as respective code on the intercom directory located behind iron gate.
not activeJan 5, 2006
building section · provide a utility shut off tool adjacent to gas meters. post adjacent diagram in public place.sec.712hc.
lack of requiered utility shut off tool.
not activeJan 5, 2006
building section · recharge/date tag expired hallway fire extinguishers.908hc.
fire exrtinguishers in the common areas are in need to be recharged.
not activeJan 5, 2006
building section · install a requiered handrail along front interior stairs leading to basement area.sec.1003.3.3 s.f.b.c.
lack of requiered handrail along interior stairs leading to basement area.
not activeJan 5, 2006
building section · 1)clean storage and gas meter areas.1306hc. 2)eliminate all flamable storage or sprinkle same.1001hc.
not activeAug 3, 2005
building section · clean and sanitize insanitary, urine stained sidewalk behind the structure,constituting an insanitary condtion.1306hc.
sidewalk behind structure is filled with pigoen droppings, urine and debries in need of daily maintanance.
not activeAug 3, 2005
building section · repair inoperative oven in apt #28.1001hc.
malfunctioning oven,in need to be serviced.
not activeAug 3, 2005
building section · weatherstrip bottom of entry door to apt #28, to prevent air infiltration and potential rodent entry.1001hc.
large upening under entry door to apt #28.
not activeAug 3, 2005
building section · remove parked motor vehicle from under rear fire escape ladder at willow alley, constituting an egress obstruction.801hc.
not activeAug 3, 2005
building section · plug up floor opening along studio wall floor junction,to prevent potential rodent entry.1001hc.
not activeAug 3, 2005
building section · 1)repair/replace damaged shower drain in apt #28, causing water damage to bathroom ceiling in apt #8.1001hc. 2)replaster and paint water damaged bathroom ceiling surfaces in apt #8 after repairs.1001hc./1301hc.
overhead leaks due to a defective shower drain.