stoop
MAP
LeaderboardAbout

1029 GEARY ST

Tenderloin · San Francisco, CA · Parcel 0715010A · Last violation Jun 25, 2026 · Last complaint Jun 27, 2026

NeighborhoodTenderloin
More violations than 100% of nearby buildings
More violations than 100% of buildings and more complaints than 99% of buildings in Tenderloin. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 39 violations · 22 complaints
'24'26ViolationsComplaints
Severityⓘopen violations
21 open DBI violations
Active Notices of Violation issued by the Department of Building Inspection.
Open fire-safety violations0
Open lead violations0
311 Housing Complaints
Total complaints since 2012
38
3 per year avg.↑ Rising — no prior history
Reported issues
22
Heatⓘ2
Leadⓘ0
Pestsⓘ14
Dept. of Building Inspection Violations
Total violations since 1997
136
5 per year avg.↑ Rising — no prior history
Open violations
21
Fire safetyⓘ0
Leadⓘ0

Top violation categories

5 yrsAll time
building sectionⓘ37 violations
other sectionⓘ34 violations
interior surfaces sectionⓘ31 violations
sanitation sectionⓘ17 violations
fire section5 violations
Unknown4 violations
plumbing and electrical sectionⓘ4 violations
smoke detection section3 violations
security requirements section1 violations

Top complaint types

5 yrsAll time
Infestation Rodent Insect11 complaints
Plumbing Broken Leaking7 complaints
Elevators No Working Elevator 7 Or More Stories6 complaints
Infestation Bed Bugs3 complaints
Garbage Receptacles3 complaints
Hot Water Lack Of Hot Water2 complaints
Elevators Everthing Else2 complaints
General Maintenance Not In List Above2 complaints
Mold And Mildew1 complaints
Blocked Exit Common Areas1 complaints
Hide violations (136) ↑See complaints (38) →

Violation log

136 DBI violations

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
OpenJun 25, 2026other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. ***correction of violations cited in this notice may require building, plumbing and/or electrical permits. it is the responsibility of the owner to obtain (or have others obtain) any required permits before beginning work that requires permit(s). when applying for a permit, reference the complaint number from this notice of violation. you must have the proper permit signed-off and finalized before the housing insp. returns in order for this violation to be abated.***
See something wrong? File a complaint with SF 311
OpenJun 25, 2026other sectionprovide heat to each occupied habitable room capable of maintaining a min. room temp. of 70 degrees f. (21 degrees c.). (701(a) hc)repair/ replace radiator to proper working condition; heat was not on at time of inspection. provide/ install heat source in bedroom (adjacement to bathroom); building and/or electrical permits required. location: apt. #34 ----------
OpenJun 25, 2026interior surfaces sectionmaintain appliances (505(g) hc)repair/ replace the following kitchen appliances that is no longer functioning properly: - refrigerator - oven and several broken knobs - dishwasher location: kitchen ----------
OpenJun 25, 2026building sectionthis notice includes violations for the areas noted.subject property located at 1029 geary st. apt. #34.
OpenJun 22, 2026plumbing and electrical sectionrepair lightswitch (1001(e) hc)restore power to common area hallway in basement level; at time of inspection, hallway ceiling lights were off. location: basement level common area hallway ----------
OpenJun 22, 2026building sectionthis notice includes violations for the areas noted.subject property located at 1029 geary st. common areas.
OpenJun 22, 2026other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. ***correction of violations cited in this notice may require building, plumbing and/or electrical permits. it is the responsibility of the owner to obtain (or have others obtain) any required permits before beginning work that requires permit(s). when applying for a permit, reference the complaint number from this notice of violation. you must have the proper permit signed-off and finalized before the housing insp. returns in order for this violation to be abated.***
OpenMay 18, 2026building sectionthis notice includes violations for the areas noted.1029 geary street unit#b5 and all common area
OpenMay 18, 2026other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. you can reach inspector lee @ 415-793-7947 or by email at joy.lee@sfgov.org.
OpenMay 18, 2026interior surfaces sectionrepair floor covering (1001b,j,o hc)at time of inspection, damaged was observed in several areas in unit#b5. repair or replace floor covering in an approved manner.
OpenMay 18, 2026sanitation sectionremove rubbish or trash (1306,1307 hc)at time of inspection, overflowing trash was observed throughout the hallways in building basement. remove all overflowing trash.
OpenMar 17, 2026building sectionthis notice includes violations for the areas noted: 1029 geary street unit#581) make necessary repairs to tub/shower (1001 hc) at time of inspection, porcelain finish on bathtub is worn and chipped so that underlying metal is exposed and is rusty making bathtub difficult to clean. repair or replace so that bathtub is cleanable. 2) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, toilet was not secured to the floor. make necessary repair to ensure toilet is secured. 3) repair clogged / slow draining drain (1001f hc) at time of inspection, kitchen sink showed sign of slow draining. make necessary repair so the sink would drain properly. 4) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, kitchen oven and 2 stove tops did not work. repair or replace kitchen stove/over in an approved manner.
OpenMar 17, 2026building sectionthis notice includes violations for the areas noted: 1029 geary street unit#411) repair floor covering (1001b,j,o hc) at time of inspection, floor coverings was cracked and damaged in unit bathroom. repair or replace floor covering in an approved manner. 2) repair damaged walls (1001b,h,o hc) at time of inspection, peeling paint was observed in unit bedroom. repair and repaint all damaged areas in an approved manner.
OpenMar 17, 2026building sectiondisturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3423, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 252-3800 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.—
OpenMar 17, 2026building sectionthis notice includes violations for the areas noted: 1029 geary street unit#291) eliminate mold/mildew on ceiling (1301,1001b(13),1306 hc) at time of inspection, mold/mildew was observed in unit bathroom. eliminate mold/mildew in an approved manner. 2) repair damaged walls (1001b,h,o hc) at time of inspection, peeling paint was observed throughout bedroom ceilings and walls. repair and repaint in an approved manner. 3) repair window (1001(h),(j),& 708 hc) at time of inspection, dry rot was noted on unit bedroom window frames and bathroom window was painted over. make necessary repair or replacement to windows/window frames.
OpenMar 17, 2026building sectionthis notice includes violations for the areas noted: 1029 geary street unit#561) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, light switch was damaged in unit hallway. repair or replace light switch in an approved manner. 2) repair damaged walls (1001b,h,o hc) at time of inspection, leak damage was observed on unit bedroom ceiling. repair and repaint in an approved manner.
OpenMar 17, 2026building sectionthis notice includes violations for the areas noted: 1029 geary street unit#441) repair damaged walls (1001b,h,o hc) at time of inspection, damages and peeling paint were observed on walls and ceilings in unit. repair and repaint all damaged areas in an approved manner. 2) eliminate mold/mildew on ceiling (1301,1001b(13),1306 hc) at time of inspection, mold/mildew was observed in unit bathroom. eliminate mold/mildew in an approved manner. 3) repair window (1001(h),(j),& 708 hc) throughout unit there are windows in different states of disrepair. ensure that all windows in unit are repaired in an approved manner and functioning correctly. all windows must open easily, remain open, close easily and close securely with a latch while being weather proofed to protect from the elements. if entire window is replaced building permit is required. 4) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, damage was observed on refrigerator seals. make necessary repair or replacement on refrigerator. 5) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, damage was observed on unit kitchen cabinet. repair or replace kitchen cabinet in an approved manner.
OpenMar 17, 2026building sectionthis notice includes violations for the areas noted: 1029 geary street unit#b41) repair floor covering (1001b,j,o hc) at time of inspection, floor coverings was peeling and damaged throughout the unit. repair or replace floor covering in an approved manner. 2) repair damaged walls (1001b,h,o hc) at time of inspection, damages were observed on walls in unit kitchen and around windows. repair and repaint all damaged areas in an approved manner. 3) eliminate mold/mildew on ceiling (1301,1001b(13),1306 hc) at time of inspection, mold/mildew was observed in unit bathroom. eliminate mold/mildew in an approved manner. 4) repair window (1001(h),(j),& 708 hc) throughout unit there are windows in different states of disrepair. ensure that all windows in unit are repaired in an approved manner and functioning correctly. all windows must open easily, remain open, close easily and close securely with a latch while being weather proofed to protect from the elements. if entire window is replaced building permit is required. 5) make necessary repairs to tub/shower (1001 hc) at time of inspection, porcelain finish on bathtub is worn and chipped so that underlying metal is exposed and is rusty making bathtub difficult to clean. repair or replace so that bathtub is cleanable. 6) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, damage was observed on unit ceiling light fixture. repair or replace light fixture.
OpenMar 17, 2026other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. you can reach inspector lee @ 415-793-7947 or by email at joy.lee@sfgov.org.
OpenMar 17, 2026building sectionthis notice includes violations for the areas noted: 1029 geary street unit#241) repair damaged walls (1001b,h,o hc) at time of inspection, leak damage and peeling paint was observed throughout unit ceilings and walls. repair and repaint in an approved manner. 2) eliminate mold/mildew on ceiling (1301,1001b(13),1306 hc) at time of inspection, mold/mildew was observed in unit bathroom. eliminate mold/mildew in an approved manner. 3) repair window (1001(h),(j),& 708 hc) throughout unit there are windows in different states of disrepair. ensure that all windows in unit are repaired in an approved manner and functioning correctly. all windows must open easily, remain open, close easily and close securely with a latch while being weather proofed to protect from the elements. if entire window is replaced building permit is required. 4) repair floor covering (1001b,j,o hc) at time of inspection, floor coverings was peeling and damaged throughout unit kitchen. repair or replace floor covering in an approved manner.
OpenMar 17, 2026building sectionthis notice includes violations for the areas noted: 1029 geary street common area1) eliminate rodent/cockroach infestation (1001-b, 1306 hc): at time of inspection, evidence of rodents and cockroaches exist in this building. have licensed pest control contractor treat building in approved manner to eliminate rodents. provide written documentation of treatment from pest control company at time of reinspection. 2) remove rubbish or trash (1306,1307 hc): at time of inspection, overflowing trash was observed in common areas. remove all overflowing trash. 3) repair all windows glazing seals, sash cords, sash frames and latches or hardware (1001(h),(j),& 708 hc): throughout the building there are windows in different states of disrepair. ensure that all windows in unit are repaired in an approved manner and functioning correctly. all windows must open easily, remain open, close easily and close securely with a latch while being weather proofed to protect from the elements. if entire window is replaced building permit is required. 4) repair damaged walls (1001b,h,o hc) at time of inspection, damaged wall was observed on a hallway wall outside of unit#41. repair and repaint in an approved manner. 5) repair deteriorated drainage pipes at exterior (1001f hc) at time of inspection, leak was observed from an exterior pipe on the building. locate and repair the source of leak in an approved manner. please attain all necessary permits, including plumbing, mechanical, electric and building permits. all permits must be finalized prior to housing inspector reinspection, in order to abate this item. 6) comply with self certification affidavit for smoke alarms and carbon monoxide detectors (420.4, 907.2.11, 3401.6.1 sfbc) return the self certification affidavit to the address listed at the bottom of the form or hand it to the inspector on scheduled re-inspection date.
not activeNov 26, 2025other sectionrepair defective or non-working elevator (1001(l), 713 hc)restore non-working elevator to proper working condition and provide documentation showing that the state permit to operate is current.
not activeNov 26, 2025building sectionthis notice includes violations for the areas noted.1029 geary street unit#34 and all common area
not activeNov 26, 2025plumbing and electrical sectionmake necessary repairs to tub/shower (1001 hc)at time of inspection, leak was observed around unit#34 bathtub area. locate and repair source of leak.
not activeNov 26, 2025plumbing and electrical sectionrepair sink (1001f hc)at time of inspection, kitchen and bathroom sinks as well as bathtub in unit#34 could not reain properly. make necessary repair or replacement in an approved manner.
not activeNov 26, 2025other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. you can reach inspector lee @ 415-793-7947 or by email at joy.lee@sfgov.org.
not activeOct 27, 2025sanitation sectioneliminate rodent infestation (1001b, 1306 hc)evidence of rodents exist in this building. there are many openings in walls and floors. these openings may serve as an entrance or harborage for rodents. seal any openings in floors, walls and ceiling of the building that are greater than 1/4 inch. have licensed pest control contractor treat building in approved manner to eliminate rodents. provide written documentation of treatment from pest control company at time of reinspection.
not activeOct 27, 2025plumbing and electrical sectionrepair deteriorated drainage pipes(1001f hc)inspection revealed sewage leak in the basement and airwell of the building. clear drain and replace cap. hire a professional drain cleaning company to thoroughly inspect sewer line to ensure proper functioning, & provide receipts.
not activeOct 27, 2025other sectionprovide apt. house or hotel water heated to min. 105 degrees f. (41 degrees c.) and max. of 120 degrees f. (49 degrees c.) at hot water taps. (505d(3))at time of inspection, no hot water was available for the building. provide water heated to min. 105 degrees f. (41 degrees c.) and max. of 120 degrees f. (49 degrees c.) at hot water taps in all units.
not activeOct 27, 2025fire sectionremove egress obstruction (801,1001(l) hc)at time of inspection, egress obstruction was observed in building basement. remove all egress obstruction immediately.
not activeOct 27, 2025sanitation sectionremove rubbish or trash (1306,1307 hc)at time of inspection, overflowing trash was observed in several areas of the building. remove all overflowing trash and sanitize the areas in an approved manner.
not activeOct 27, 2025other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. you can reach inspector lee @ 415-793-7947 or by email at joy.lee@sfgov.org.
not activeOct 27, 2025building sectionthis notice includes violations for the areas noted.1029 geary street and all common area
not activeOct 27, 2025other sectionprovide heat to each occupied habitable room capable of maintaining a min. room temp. of 70 degrees f. (21 degrees c.). (701(a) hc)at the time of inspection no heat was available in the building. provide adequate heat to habitable rooms in all units. work for this must begin within 3 working days of receiving this notice. if new heating source is installed, please attain all necessary permits, including plumbing, mechanical, electric and building permits. all permits must be finalized prior to housing inspector reinspection, in order to abate this item.
not activeJul 7, 2025other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeJul 7, 2025interior surfaces sectionrepair damaged ceiling (1001(b),(h),(o) hc)repair damaged ceiling in an approved manner; observed hole in ceiling of bedroom closet at time inspection. location: bdrm closet ----------
not activeJul 7, 2025building sectionthis notice includes violations for the areas noted.subject property located at 1029 geary st. apt. #68.
not activeMay 1, 2025———
not activeMay 1, 2025———
not activeSep 25, 2019other sectioninspector commentsimportant note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeSep 25, 2019building sectionprovide elevator service, nuisance 505c, 713, 1001d, l, 1002b sfhcat the time of inspection the elevator was not in service. repair/restore/replace the elevator as necessary within the specified time frame listed below.
not activeSep 25, 2019building sectionthis notice includes violations for the areas noted.this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 1029 geary street.
not activeAug 6, 2015building sectionthis notice includes violations for the areas noted.1029 geary street
not activeAug 6, 2015interior surfaces sectionrepair elevator (1001b, 713 hc)restore elevator to proper working order.
not activeAug 6, 2015other sectioninspector commentsdue to the violations noted, this constitutes a nuisance per the san francisco housing code section 1001(d) it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeJan 13, 2015———
not activeJan 6, 2015building sectionthis notice includes violations for the areas noted.this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 1029 geary street, unit 54.
not activeJan 6, 2015sanitation sectioneliminate cockroach infestation (1001b, 1306 hc)there were cockroaches in the base cabinets to the left of the kitchen sink in this unit. the basement trash area was also infested. eliminate cockroach infestation at all apartment locations. pest control should be performed in all rooms whether occupied or not and in all common areas of the building. provide housing inspector all pest control reports and certifications at the time of re-inspection. all certifications should follow the protocol from the department of public health.
not activeJan 6, 2015other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeMar 3, 2014fire sectionrepair or replace smoke detectors (702)(911)hc, (310.9.1.2)cbcrepair or replace the smoke detectors in the common areas.
OpenJun 25, 2026
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. ***correction of violations cited in this notice may require building, plumbing and/or electrical permits. it is the responsibility of the owner to obtain (or have others obtain) any required permits before beginning work that requires permit(s). when applying for a permit, reference the complaint number from this notice of violation. you must have the proper permit signed-off and finalized before the housing insp. returns in order for this violation to be abated.***
OpenJun 25, 2026
other section · provide heat to each occupied habitable room capable of maintaining a min. room temp. of 70 degrees f. (21 degrees c.). (701(a) hc)
repair/ replace radiator to proper working condition; heat was not on at time of inspection. provide/ install heat source in bedroom (adjacement to bathroom); building and/or electrical permits required. location: apt. #34 ----------
OpenJun 25, 2026
interior surfaces section · maintain appliances (505(g) hc)
repair/ replace the following kitchen appliances that is no longer functioning properly: - refrigerator - oven and several broken knobs - dishwasher location: kitchen ----------
OpenJun 25, 2026
building section · this notice includes violations for the areas noted.
subject property located at 1029 geary st. apt. #34.
OpenJun 22, 2026
plumbing and electrical section · repair lightswitch (1001(e) hc)
restore power to common area hallway in basement level; at time of inspection, hallway ceiling lights were off. location: basement level common area hallway ----------
OpenJun 22, 2026
building section · this notice includes violations for the areas noted.
subject property located at 1029 geary st. common areas.
OpenJun 22, 2026
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. ***correction of violations cited in this notice may require building, plumbing and/or electrical permits. it is the responsibility of the owner to obtain (or have others obtain) any required permits before beginning work that requires permit(s). when applying for a permit, reference the complaint number from this notice of violation. you must have the proper permit signed-off and finalized before the housing insp. returns in order for this violation to be abated.***
OpenMay 18, 2026
building section · this notice includes violations for the areas noted.
1029 geary street unit#b5 and all common area
OpenMay 18, 2026
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. you can reach inspector lee @ 415-793-7947 or by email at joy.lee@sfgov.org.
OpenMay 18, 2026
interior surfaces section · repair floor covering (1001b,j,o hc)
at time of inspection, damaged was observed in several areas in unit#b5. repair or replace floor covering in an approved manner.
OpenMay 18, 2026
sanitation section · remove rubbish or trash (1306,1307 hc)
at time of inspection, overflowing trash was observed throughout the hallways in building basement. remove all overflowing trash.
OpenMar 17, 2026
building section · this notice includes violations for the areas noted: 1029 geary street unit#58
1) make necessary repairs to tub/shower (1001 hc) at time of inspection, porcelain finish on bathtub is worn and chipped so that underlying metal is exposed and is rusty making bathtub difficult to clean. repair or replace so that bathtub is cleanable. 2) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, toilet was not secured to the floor. make necessary repair to ensure toilet is secured. 3) repair clogged / slow draining drain (1001f hc) at time of inspection, kitchen sink showed sign of slow draining. make necessary repair so the sink would drain properly. 4) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, kitchen oven and 2 stove tops did not work. repair or replace kitchen stove/over in an approved manner.
OpenMar 17, 2026
building section · this notice includes violations for the areas noted: 1029 geary street unit#41
1) repair floor covering (1001b,j,o hc) at time of inspection, floor coverings was cracked and damaged in unit bathroom. repair or replace floor covering in an approved manner. 2) repair damaged walls (1001b,h,o hc) at time of inspection, peeling paint was observed in unit bedroom. repair and repaint all damaged areas in an approved manner.
OpenMar 17, 2026
building section · disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal : always wet the surface, contain and properly dispose of leaded paint. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3423, sfbc) informational packets are available at (415) 558-6088. you can contact the san francisco childhood lead poisoning prevention program at: (415) 252-3800 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by the dust. ordinance #446-97.
OpenMar 17, 2026
building section · this notice includes violations for the areas noted: 1029 geary street unit#29
1) eliminate mold/mildew on ceiling (1301,1001b(13),1306 hc) at time of inspection, mold/mildew was observed in unit bathroom. eliminate mold/mildew in an approved manner. 2) repair damaged walls (1001b,h,o hc) at time of inspection, peeling paint was observed throughout bedroom ceilings and walls. repair and repaint in an approved manner. 3) repair window (1001(h),(j),& 708 hc) at time of inspection, dry rot was noted on unit bedroom window frames and bathroom window was painted over. make necessary repair or replacement to windows/window frames.
OpenMar 17, 2026
building section · this notice includes violations for the areas noted: 1029 geary street unit#56
1) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, light switch was damaged in unit hallway. repair or replace light switch in an approved manner. 2) repair damaged walls (1001b,h,o hc) at time of inspection, leak damage was observed on unit bedroom ceiling. repair and repaint in an approved manner.
OpenMar 17, 2026
building section · this notice includes violations for the areas noted: 1029 geary street unit#44
1) repair damaged walls (1001b,h,o hc) at time of inspection, damages and peeling paint were observed on walls and ceilings in unit. repair and repaint all damaged areas in an approved manner. 2) eliminate mold/mildew on ceiling (1301,1001b(13),1306 hc) at time of inspection, mold/mildew was observed in unit bathroom. eliminate mold/mildew in an approved manner. 3) repair window (1001(h),(j),& 708 hc) throughout unit there are windows in different states of disrepair. ensure that all windows in unit are repaired in an approved manner and functioning correctly. all windows must open easily, remain open, close easily and close securely with a latch while being weather proofed to protect from the elements. if entire window is replaced building permit is required. 4) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, damage was observed on refrigerator seals. make necessary repair or replacement on refrigerator. 5) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, damage was observed on unit kitchen cabinet. repair or replace kitchen cabinet in an approved manner.
OpenMar 17, 2026
building section · this notice includes violations for the areas noted: 1029 geary street unit#b4
1) repair floor covering (1001b,j,o hc) at time of inspection, floor coverings was peeling and damaged throughout the unit. repair or replace floor covering in an approved manner. 2) repair damaged walls (1001b,h,o hc) at time of inspection, damages were observed on walls in unit kitchen and around windows. repair and repaint all damaged areas in an approved manner. 3) eliminate mold/mildew on ceiling (1301,1001b(13),1306 hc) at time of inspection, mold/mildew was observed in unit bathroom. eliminate mold/mildew in an approved manner. 4) repair window (1001(h),(j),& 708 hc) throughout unit there are windows in different states of disrepair. ensure that all windows in unit are repaired in an approved manner and functioning correctly. all windows must open easily, remain open, close easily and close securely with a latch while being weather proofed to protect from the elements. if entire window is replaced building permit is required. 5) make necessary repairs to tub/shower (1001 hc) at time of inspection, porcelain finish on bathtub is worn and chipped so that underlying metal is exposed and is rusty making bathtub difficult to clean. repair or replace so that bathtub is cleanable. 6) general dilapidation or improper maintenance (1001 (b)(13)) at time of inspection, damage was observed on unit ceiling light fixture. repair or replace light fixture.
OpenMar 17, 2026
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. you can reach inspector lee @ 415-793-7947 or by email at joy.lee@sfgov.org.
OpenMar 17, 2026
building section · this notice includes violations for the areas noted: 1029 geary street unit#24
1) repair damaged walls (1001b,h,o hc) at time of inspection, leak damage and peeling paint was observed throughout unit ceilings and walls. repair and repaint in an approved manner. 2) eliminate mold/mildew on ceiling (1301,1001b(13),1306 hc) at time of inspection, mold/mildew was observed in unit bathroom. eliminate mold/mildew in an approved manner. 3) repair window (1001(h),(j),& 708 hc) throughout unit there are windows in different states of disrepair. ensure that all windows in unit are repaired in an approved manner and functioning correctly. all windows must open easily, remain open, close easily and close securely with a latch while being weather proofed to protect from the elements. if entire window is replaced building permit is required. 4) repair floor covering (1001b,j,o hc) at time of inspection, floor coverings was peeling and damaged throughout unit kitchen. repair or replace floor covering in an approved manner.
OpenMar 17, 2026
building section · this notice includes violations for the areas noted: 1029 geary street common area
1) eliminate rodent/cockroach infestation (1001-b, 1306 hc): at time of inspection, evidence of rodents and cockroaches exist in this building. have licensed pest control contractor treat building in approved manner to eliminate rodents. provide written documentation of treatment from pest control company at time of reinspection. 2) remove rubbish or trash (1306,1307 hc): at time of inspection, overflowing trash was observed in common areas. remove all overflowing trash. 3) repair all windows glazing seals, sash cords, sash frames and latches or hardware (1001(h),(j),& 708 hc): throughout the building there are windows in different states of disrepair. ensure that all windows in unit are repaired in an approved manner and functioning correctly. all windows must open easily, remain open, close easily and close securely with a latch while being weather proofed to protect from the elements. if entire window is replaced building permit is required. 4) repair damaged walls (1001b,h,o hc) at time of inspection, damaged wall was observed on a hallway wall outside of unit#41. repair and repaint in an approved manner. 5) repair deteriorated drainage pipes at exterior (1001f hc) at time of inspection, leak was observed from an exterior pipe on the building. locate and repair the source of leak in an approved manner. please attain all necessary permits, including plumbing, mechanical, electric and building permits. all permits must be finalized prior to housing inspector reinspection, in order to abate this item. 6) comply with self certification affidavit for smoke alarms and carbon monoxide detectors (420.4, 907.2.11, 3401.6.1 sfbc) return the self certification affidavit to the address listed at the bottom of the form or hand it to the inspector on scheduled re-inspection date.
not activeNov 26, 2025
other section · repair defective or non-working elevator (1001(l), 713 hc)
restore non-working elevator to proper working condition and provide documentation showing that the state permit to operate is current.
not activeNov 26, 2025
building section · this notice includes violations for the areas noted.
1029 geary street unit#34 and all common area
not activeNov 26, 2025
plumbing and electrical section · make necessary repairs to tub/shower (1001 hc)
at time of inspection, leak was observed around unit#34 bathtub area. locate and repair source of leak.
not activeNov 26, 2025
plumbing and electrical section · repair sink (1001f hc)
at time of inspection, kitchen and bathroom sinks as well as bathtub in unit#34 could not reain properly. make necessary repair or replacement in an approved manner.
not activeNov 26, 2025
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. you can reach inspector lee @ 415-793-7947 or by email at joy.lee@sfgov.org.
not activeOct 27, 2025
sanitation section · eliminate rodent infestation (1001b, 1306 hc)
evidence of rodents exist in this building. there are many openings in walls and floors. these openings may serve as an entrance or harborage for rodents. seal any openings in floors, walls and ceiling of the building that are greater than 1/4 inch. have licensed pest control contractor treat building in approved manner to eliminate rodents. provide written documentation of treatment from pest control company at time of reinspection.
not activeOct 27, 2025
plumbing and electrical section · repair deteriorated drainage pipes(1001f hc)
inspection revealed sewage leak in the basement and airwell of the building. clear drain and replace cap. hire a professional drain cleaning company to thoroughly inspect sewer line to ensure proper functioning, & provide receipts.
not activeOct 27, 2025
other section · provide apt. house or hotel water heated to min. 105 degrees f. (41 degrees c.) and max. of 120 degrees f. (49 degrees c.) at hot water taps. (505d(3))
at time of inspection, no hot water was available for the building. provide water heated to min. 105 degrees f. (41 degrees c.) and max. of 120 degrees f. (49 degrees c.) at hot water taps in all units.
not activeOct 27, 2025
fire section · remove egress obstruction (801,1001(l) hc)
at time of inspection, egress obstruction was observed in building basement. remove all egress obstruction immediately.
not activeOct 27, 2025
sanitation section · remove rubbish or trash (1306,1307 hc)
at time of inspection, overflowing trash was observed in several areas of the building. remove all overflowing trash and sanitize the areas in an approved manner.
not activeOct 27, 2025
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector. provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. you can reach inspector lee @ 415-793-7947 or by email at joy.lee@sfgov.org.
not activeOct 27, 2025
building section · this notice includes violations for the areas noted.
1029 geary street and all common area
not activeOct 27, 2025
other section · provide heat to each occupied habitable room capable of maintaining a min. room temp. of 70 degrees f. (21 degrees c.). (701(a) hc)
at the time of inspection no heat was available in the building. provide adequate heat to habitable rooms in all units. work for this must begin within 3 working days of receiving this notice. if new heating source is installed, please attain all necessary permits, including plumbing, mechanical, electric and building permits. all permits must be finalized prior to housing inspector reinspection, in order to abate this item.
not activeJul 7, 2025
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeJul 7, 2025
interior surfaces section · repair damaged ceiling (1001(b),(h),(o) hc)
repair damaged ceiling in an approved manner; observed hole in ceiling of bedroom closet at time inspection. location: bdrm closet ----------
not activeJul 7, 2025
building section · this notice includes violations for the areas noted.
subject property located at 1029 geary st. apt. #68.
not activeMay 1, 2025
—
not activeMay 1, 2025
—
not activeSep 25, 2019
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeSep 25, 2019
building section · provide elevator service, nuisance 505c, 713, 1001d, l, 1002b sfhc
at the time of inspection the elevator was not in service. repair/restore/replace the elevator as necessary within the specified time frame listed below.
not activeSep 25, 2019
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 1029 geary street.
not activeAug 6, 2015
building section · this notice includes violations for the areas noted.
1029 geary street
not activeAug 6, 2015
interior surfaces section · repair elevator (1001b, 713 hc)
restore elevator to proper working order.
not activeAug 6, 2015
other section · inspector comments
due to the violations noted, this constitutes a nuisance per the san francisco housing code section 1001(d) it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeJan 13, 2015
—
not activeJan 6, 2015
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 1029 geary street, unit 54.
not activeJan 6, 2015
sanitation section · eliminate cockroach infestation (1001b, 1306 hc)
there were cockroaches in the base cabinets to the left of the kitchen sink in this unit. the basement trash area was also infested. eliminate cockroach infestation at all apartment locations. pest control should be performed in all rooms whether occupied or not and in all common areas of the building. provide housing inspector all pest control reports and certifications at the time of re-inspection. all certifications should follow the protocol from the department of public health.
not activeJan 6, 2015
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeMar 3, 2014
fire section · repair or replace smoke detectors (702)(911)hc, (310.9.1.2)cbc
repair or replace the smoke detectors in the common areas.
Page 1 of 3