stoop
MAP
LeaderboardAbout

44 MCALLISTER ST

Tenderloin · San Francisco, CA · Parcel 0349004 · Last violation May 15, 2026 · Last complaint Nov 6, 2025

NeighborhoodTenderloin
More violations than 86% of nearby buildings
More violations than 86% of buildings and more complaints than 82% of buildings in Tenderloin. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 22 violations · 13 complaints
'21'26ViolationsComplaints
Severityⓘopen violations
19 open DBI violations
Active Notices of Violation issued by the Department of Building Inspection.
Open fire-safety violations0
Open lead violations0
311 Housing Complaints
Total complaints since 2010
78
5 per year avg.↓ Down 24% in the last 2 years (13 vs 17 prior 2 yrs)
Reported issues
13
Heatⓘ3
Leadⓘ2
Pestsⓘ23
Dept. of Building Inspection Violations
Total violations since 1998
217
7 per year avg.↓ Down 41% in the last 2 years (22 vs 37 prior 2 yrs)
Open violations
19
Fire safetyⓘ0
Leadⓘ0

Top violation categories

5 yrsAll time
building sectionⓘ67 violations
other sectionⓘ48 violations
interior surfaces sectionⓘ31 violations
plumbing and electrical sectionⓘ31 violations
sanitation sectionⓘ14 violations
fire section10 violations
Unknownⓘ8 violations
security requirements section4 violations
smoke detection section4 violations

Top complaint types

5 yrsAll time
Infestation Rodent Insect17 complaints
Mold And Mildew15 complaints
General Maintenance Not In List Above8 complaints
Infestation Bed Bugs6 complaints
Plumbing Broken Leaking6 complaints
Ventilation Inadequate Or None3 complaints
Heat Lack Of Heat3 complaints
Elevators No Working Elevator 7 Or More Stories3 complaints
Paint Lead Violating Safe Practices2 complaints
Doors Windows Broken Defective2 complaints
Fire Alarm System2 complaints
Fire Hazard2 complaints
Paint Peeling2 complaints
Visitor Policy Violations1 complaints
Clutter Hoarder Unit Interior Storage1 complaints
Electrical Hazardous Condition1 complaints
Electrical Non Hazard1 complaints
Elevators Everthing Else1 complaints
Security Inadequately Secured Perimeter1 complaints
Bathroom1 complaints
Hide violations (217) ↑See complaints (78) →

Violation log

217 DBI violations

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
not activeMar 2, 2007other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
See something wrong? File a complaint with SF 311
not activeFeb 5, 2007fire sectionother fire violation (1001 b,i hc)the fire alarm call box near #331 has been torn from the wall. re-attach the call box to the wall and insure that it is in working order.
not activeFeb 5, 2007sanitation sectionclear the garbage chutes (1001b hc)clear the blocked garbage chutes.
not activeFeb 5, 2007smoke detection sectionprovide smoke detector at stairs (911 hc)install a smoke alarm at the top of each stairway. this can be a battery operated alarm.
not activeFeb 5, 2007fire sectionpermanently remove combustible storage or provide automatic fire sprinklers. (904, 1001(i) hc)remove the combustable storage in the following locations: 1)house phone room near #704, 2)mattresses, etc. stored under the rear fire escape.
not activeFeb 5, 2007security requirements sectionprovide designated missing unit/apartment identification numbers to all units (706 hc)provide a door number for #205.
not activeFeb 5, 2007interior surfaces sectionrepair/install damaged or missing ventilation (1001b,g hc)repair or install a ventilation fan the following locations: 1)#205 bathroom, 2)common bath near #329.
not activeFeb 5, 2007other sectioninspector commentsnote: on reinspection day, property manager, owner or the owner's agent needs to demonstrate the workability of the fire escape ladders. the fire escapes are to be checked on all buildings during the course of a routine inspection. non-working fire escape ladder is a life safety hazard and must be corrected immediately. provide a written and signed report from a qualified service company or contractor stating that all parts and cables have been tested and are functional or you are required to lower the ladder on re-inspection day to verify its proper full release. reminder: test and verify that all windows or doors leading to emergency fire escape are operational and unobstructed. advise occupants not to block the path of emergency exits on the inside. **reminder**all manufacturers recommend that the fire escape drop ladder be maintained and serviced annually, particularly the cable and all moving parts. lubricate and drop the ladder at least once a year.
not activeFeb 5, 2007fire sectionrecharge/date tag fire extinguisher type 2a 10bc or equivalent (905,1001(m)hc)the date tags and guages for most fire extinguishers are unreadable. position the extinguishers in their cabinets so both can be read. fire extinguishers must be recharged and retagged annually.
not activeFeb 5, 2007security requirements sectionadjudt door closer (1001 b, j hc)adjust the tradesmans door closer so that it closes and latches the door.
not activeFeb 5, 2007building sectionremove/repair thermostat (1001 b hc)in the bathrooms near #'s 825,725,& 425 are damaged thermostats to inoperble (?) heat exchange units. remove/replace/repair these thermostats in that the mercury within pose a health hazard if released.
not activeFeb 5, 2007building sectionrepair window latches or hardware (1001(b)hc)repair/replace the broken window handle to the left bedroom window in #205.
not activeFeb 5, 2007plumbing and electrical sectionremove cord wiring (1001-e hc)remove the cord wiring powering the wall light fixture near door c on the second floor.
not activeFeb 5, 2007interior surfaces sectionpaint ceilings & walls (1001b,1301 hc)prep and paint the peeling damaged surfaces in the following locations: 1)common bathroom near #225, 2)common bath near #327.
not activeFeb 5, 2007building sectionrepair weather proofing on siding (1001(h),703 hc)seal around the pipe passing through the exterior wall in the bathroom near #725.
not activeFeb 5, 2007building sectionrepair entry threshold (1001b, j hc)the threshold for the main entry door is loose and a trip hazard. repair or replace.
not activeFeb 5, 2007other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. at the time of reinspection provide access to all common areas including the roof, boiler, timeclock, thermostat, and all storage areas. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeFeb 5, 2007plumbing and electrical sectionrepair deteriorated drainage pipes at exterior (1001f hc)the drain for the west tradesmans alley outside the rear entry door appears blocked. clear the drain and attach a drain cover.
not activeFeb 5, 2007plumbing and electrical sectionrepair electrical outlet (1001e hc)the electrical outlet in the front fire escape corridor on the seventh floor appears to have shorted out. replace the outlet or confirm that it is in good working order.
not activeFeb 5, 2007fire sectionremove egress obstruction at (801,1001(l) hc)the garbage receptacles stored in the east tradesmans alley are obstructing an emergency path of egress. move the receptacles to the rear yard.
not activeFeb 5, 2007plumbing and electrical sectionrepair toilet (1001f hc)repair the running toilet in #205.
not activeFeb 5, 2007other sectioninspector commentstest the emergency lighting in the stairways to insure they are in good operating condition.
not activeFeb 5, 2007fire sectionkeep smoke enclosure doors closed (807 hc)the fire doors leading to the rear fire escape were tied open on the 7th & 8th floors. these doors should remain closed.
not activeJul 12, 2005building section1)have a non temperable centrally located thermostat installed by a c10 licensed contractor. 701hc./1001hc. 2)provide 68 degrees to each habitable room between : 5:00 am-11:00 am 3:00 pm-10:00 pm. 701hc.lack of a requiered thermostat on the premises.
not activeFeb 7, 2005building sectionremove,treat and eliminate source of mildew under and around guestroom window in gr#517.1306hc.mildewed wall surfaces under guestgroom window.
not activeFeb 7, 2005building sectionclean and sanitize wall and ceiling surfaces in the: 1)community kitchen area side of stove,above the couter. 2)remove grease and dust from kitchen windows,lint from laundry room windows. 3)degrease hood and vent system. 4)degrease and clean fan housing. 5)remove lint from wall surfaces behind washer and dryer,on routine basis. 6)keep and maintain public areas in a clean and sanitary condition at all times.1306hc./1001hc.insanitary public areas.
not activeFeb 19, 2004building sectionloose detached hard wired smoke detector .repair or replace smoke detector unit in gr#519.908hc.
not activeFeb 19, 2004building sectioninadequate weather protection under entry door to gr#519.weathersrip bottom of entry door to gr#519, to prevent air infiltration.1001hc.
not activeFeb 19, 2004building sectioncracked caulking around handwash basinreplace damaged cauling around,side of hand wash basin.1001hc. 2)caulk areaaround top of steam pipe to prevent roach harborage.1001hc.
not activeDec 19, 2003building sectionlack of radiator units in a variety of guestrooms.1)install a radiator unit in the fallowing guestrooms: gr.#201b #201c #212 #220 #223 #307 #327 #400 #404 #521 #610 #628 #632 #815 #816. 1001hc. 2) provide 68 degrees f. to each habitable room.701hc.
not activeNov 10, 2003building sectionleaking bathroom faucet in 2nd floor public bathroom.1repair/repack leaking second floor public bathroom faucet.1001hc.
not activeNov 10, 2003other sectioninspector commentsit is the property owner?s responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b)), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeNov 10, 2003other sectioninspector commentsit is the property owner?s responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b)), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeNov 10, 2003building sectionlack of radiator unit in gr#519.1)install a radiator unit in gr#519.1001hc. 2)provide 68 degrees f. from 5:00 am-11:00 am 3:00 pm-10:00 pm sec. 701hc.
not activeNov 10, 2003building sectionbroken cover plate to 2nd floor public bathroom,exposed wiring.replace broken cover plate in second floor public bathroom.1001hc.
not activeNov 10, 2003building sectiondefective toilet seat in 5th floor bathroomreplace defective toilet seat in 5th floor bathroom.1001hc.
not activeNov 10, 2003building section5th floor toilet partitions in need to be cleaned and sanitized.wash down ,clean and sanitize 5th floor toilet partitions.1306hc.
not activeFeb 21, 2003building sectionextensive mold and mildew along guestroom/closet wall surfaces.a)locate source,remove,treat,and contain mold and mildew along guestroom wall surfaces : 1)side of bed. 2)linen closet. bclean,sanitize or replace carpeting reportedly filled with human urine stains and excrement.1306hc.
not activeJan 29, 2003building sectionfailure to file for necessary permits in order to comply with the residential hotel sprinkler ordinance #170-02.submit a building permit application with plans to the department of building inspection within 15 days of this notice to comply with the residential hotel sprinkler ordinance #170-02, section 904 s.f.h.c.
not activeMar 28, 2002building sectionwater damaged 3rd floor hallway ceiling.resheetrock/replaster and paint water damaged ceiling surfaces in 3rd floor hallway.1001hc.
not activeMar 28, 2002building sectionwater damaged linen closet,walls and ceiling surfaces in #324.1)replace all buckling,soaked water damaged plaster in gr#324.1001hc. 2)replaster and paint unit #324.1301hc.
not activeMar 28, 2002building sectiondefective waste pipe in #531,431,causing overhead leaks and ceiling damage on 3rd floor hallway ceiling as well as in #324.repair /replace defective waste line in gr#531,431.(hand wash basin )1001hc.
not activeJan 5, 2001———
not activeSep 26, 2000building sectioncracked walls and ceiling surfaces.replaster and paint walls and ceiling surfaces in #625.1001hc./1301hc.
not activeSep 26, 2000building sectionmissing radiator unitinstall a radiator unit to the premises.701hc.
not activeSep 26, 2000building sectioninsanitary carpeting.replace insanitary carpeting.1306hc.
not activeSep 26, 2000building sectionlack of a hard wired smoke detector.replace missing hard wired smoke detector.908hc.
not activeSep 26, 2000building sectioninsanitary premisesclean and sanitize premises throughout.1306hc.
not activeSep 26, 2000building sectiondamaged steam line wrapping.rewrap damaged portion of steam line in unit #625.1001hc.
not activeDec 29, 1998other sectionmiscellaneous violationsrepair heater in room #622 (heater is leaking on to carpet ) sfhc 701.
not activeMar 2, 2007
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeFeb 5, 2007
fire section · other fire violation (1001 b,i hc)
the fire alarm call box near #331 has been torn from the wall. re-attach the call box to the wall and insure that it is in working order.
not activeFeb 5, 2007
sanitation section · clear the garbage chutes (1001b hc)
clear the blocked garbage chutes.
not activeFeb 5, 2007
smoke detection section · provide smoke detector at stairs (911 hc)
install a smoke alarm at the top of each stairway. this can be a battery operated alarm.
not activeFeb 5, 2007
fire section · permanently remove combustible storage or provide automatic fire sprinklers. (904, 1001(i) hc)
remove the combustable storage in the following locations: 1)house phone room near #704, 2)mattresses, etc. stored under the rear fire escape.
not activeFeb 5, 2007
security requirements section · provide designated missing unit/apartment identification numbers to all units (706 hc)
provide a door number for #205.
not activeFeb 5, 2007
interior surfaces section · repair/install damaged or missing ventilation (1001b,g hc)
repair or install a ventilation fan the following locations: 1)#205 bathroom, 2)common bath near #329.
not activeFeb 5, 2007
other section · inspector comments
note: on reinspection day, property manager, owner or the owner's agent needs to demonstrate the workability of the fire escape ladders. the fire escapes are to be checked on all buildings during the course of a routine inspection. non-working fire escape ladder is a life safety hazard and must be corrected immediately. provide a written and signed report from a qualified service company or contractor stating that all parts and cables have been tested and are functional or you are required to lower the ladder on re-inspection day to verify its proper full release. reminder: test and verify that all windows or doors leading to emergency fire escape are operational and unobstructed. advise occupants not to block the path of emergency exits on the inside. **reminder**all manufacturers recommend that the fire escape drop ladder be maintained and serviced annually, particularly the cable and all moving parts. lubricate and drop the ladder at least once a year.
not activeFeb 5, 2007
fire section · recharge/date tag fire extinguisher type 2a 10bc or equivalent (905,1001(m)hc)
the date tags and guages for most fire extinguishers are unreadable. position the extinguishers in their cabinets so both can be read. fire extinguishers must be recharged and retagged annually.
not activeFeb 5, 2007
security requirements section · adjudt door closer (1001 b, j hc)
adjust the tradesmans door closer so that it closes and latches the door.
not activeFeb 5, 2007
building section · remove/repair thermostat (1001 b hc)
in the bathrooms near #'s 825,725,& 425 are damaged thermostats to inoperble (?) heat exchange units. remove/replace/repair these thermostats in that the mercury within pose a health hazard if released.
not activeFeb 5, 2007
building section · repair window latches or hardware (1001(b)hc)
repair/replace the broken window handle to the left bedroom window in #205.
not activeFeb 5, 2007
plumbing and electrical section · remove cord wiring (1001-e hc)
remove the cord wiring powering the wall light fixture near door c on the second floor.
not activeFeb 5, 2007
interior surfaces section · paint ceilings & walls (1001b,1301 hc)
prep and paint the peeling damaged surfaces in the following locations: 1)common bathroom near #225, 2)common bath near #327.
not activeFeb 5, 2007
building section · repair weather proofing on siding (1001(h),703 hc)
seal around the pipe passing through the exterior wall in the bathroom near #725.
not activeFeb 5, 2007
building section · repair entry threshold (1001b, j hc)
the threshold for the main entry door is loose and a trip hazard. repair or replace.
not activeFeb 5, 2007
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. at the time of reinspection provide access to all common areas including the roof, boiler, timeclock, thermostat, and all storage areas. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeFeb 5, 2007
plumbing and electrical section · repair deteriorated drainage pipes at exterior (1001f hc)
the drain for the west tradesmans alley outside the rear entry door appears blocked. clear the drain and attach a drain cover.
not activeFeb 5, 2007
plumbing and electrical section · repair electrical outlet (1001e hc)
the electrical outlet in the front fire escape corridor on the seventh floor appears to have shorted out. replace the outlet or confirm that it is in good working order.
not activeFeb 5, 2007
fire section · remove egress obstruction at (801,1001(l) hc)
the garbage receptacles stored in the east tradesmans alley are obstructing an emergency path of egress. move the receptacles to the rear yard.
not activeFeb 5, 2007
plumbing and electrical section · repair toilet (1001f hc)
repair the running toilet in #205.
not activeFeb 5, 2007
other section · inspector comments
test the emergency lighting in the stairways to insure they are in good operating condition.
not activeFeb 5, 2007
fire section · keep smoke enclosure doors closed (807 hc)
the fire doors leading to the rear fire escape were tied open on the 7th & 8th floors. these doors should remain closed.
not activeJul 12, 2005
building section · 1)have a non temperable centrally located thermostat installed by a c10 licensed contractor. 701hc./1001hc. 2)provide 68 degrees to each habitable room between : 5:00 am-11:00 am 3:00 pm-10:00 pm. 701hc.
lack of a requiered thermostat on the premises.
not activeFeb 7, 2005
building section · remove,treat and eliminate source of mildew under and around guestroom window in gr#517.1306hc.
mildewed wall surfaces under guestgroom window.
not activeFeb 7, 2005
building section · clean and sanitize wall and ceiling surfaces in the: 1)community kitchen area side of stove,above the couter. 2)remove grease and dust from kitchen windows,lint from laundry room windows. 3)degrease hood and vent system. 4)degrease and clean fan housing. 5)remove lint from wall surfaces behind washer and dryer,on routine basis. 6)keep and maintain public areas in a clean and sanitary condition at all times.1306hc./1001hc.
insanitary public areas.
not activeFeb 19, 2004
building section · loose detached hard wired smoke detector .
repair or replace smoke detector unit in gr#519.908hc.
not activeFeb 19, 2004
building section · inadequate weather protection under entry door to gr#519.
weathersrip bottom of entry door to gr#519, to prevent air infiltration.1001hc.
not activeFeb 19, 2004
building section · cracked caulking around handwash basin
replace damaged cauling around,side of hand wash basin.1001hc. 2)caulk areaaround top of steam pipe to prevent roach harborage.1001hc.
not activeDec 19, 2003
building section · lack of radiator units in a variety of guestrooms.
1)install a radiator unit in the fallowing guestrooms: gr.#201b #201c #212 #220 #223 #307 #327 #400 #404 #521 #610 #628 #632 #815 #816. 1001hc. 2) provide 68 degrees f. to each habitable room.701hc.
not activeNov 10, 2003
building section · leaking bathroom faucet in 2nd floor public bathroom.
1repair/repack leaking second floor public bathroom faucet.1001hc.
not activeNov 10, 2003
other section · inspector comments
it is the property owner?s responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b)), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeNov 10, 2003
other section · inspector comments
it is the property owner?s responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b)), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeNov 10, 2003
building section · lack of radiator unit in gr#519.
1)install a radiator unit in gr#519.1001hc. 2)provide 68 degrees f. from 5:00 am-11:00 am 3:00 pm-10:00 pm sec. 701hc.
not activeNov 10, 2003
building section · broken cover plate to 2nd floor public bathroom,exposed wiring.
replace broken cover plate in second floor public bathroom.1001hc.
not activeNov 10, 2003
building section · defective toilet seat in 5th floor bathroom
replace defective toilet seat in 5th floor bathroom.1001hc.
not activeNov 10, 2003
building section · 5th floor toilet partitions in need to be cleaned and sanitized.
wash down ,clean and sanitize 5th floor toilet partitions.1306hc.
not activeFeb 21, 2003
building section · extensive mold and mildew along guestroom/closet wall surfaces.
a)locate source,remove,treat,and contain mold and mildew along guestroom wall surfaces : 1)side of bed. 2)linen closet. bclean,sanitize or replace carpeting reportedly filled with human urine stains and excrement.1306hc.
not activeJan 29, 2003
building section · failure to file for necessary permits in order to comply with the residential hotel sprinkler ordinance #170-02.
submit a building permit application with plans to the department of building inspection within 15 days of this notice to comply with the residential hotel sprinkler ordinance #170-02, section 904 s.f.h.c.
not activeMar 28, 2002
building section · water damaged 3rd floor hallway ceiling.
resheetrock/replaster and paint water damaged ceiling surfaces in 3rd floor hallway.1001hc.
not activeMar 28, 2002
building section · water damaged linen closet,walls and ceiling surfaces in #324.
1)replace all buckling,soaked water damaged plaster in gr#324.1001hc. 2)replaster and paint unit #324.1301hc.
not activeMar 28, 2002
building section · defective waste pipe in #531,431,causing overhead leaks and ceiling damage on 3rd floor hallway ceiling as well as in #324.
repair /replace defective waste line in gr#531,431.(hand wash basin )1001hc.
not activeJan 5, 2001
—
not activeSep 26, 2000
building section · cracked walls and ceiling surfaces.
replaster and paint walls and ceiling surfaces in #625.1001hc./1301hc.
not activeSep 26, 2000
building section · missing radiator unit
install a radiator unit to the premises.701hc.
not activeSep 26, 2000
building section · insanitary carpeting.
replace insanitary carpeting.1306hc.
not activeSep 26, 2000
building section · lack of a hard wired smoke detector.
replace missing hard wired smoke detector.908hc.
not activeSep 26, 2000
building section · insanitary premises
clean and sanitize premises throughout.1306hc.
not activeSep 26, 2000
building section · damaged steam line wrapping.
rewrap damaged portion of steam line in unit #625.1001hc.
not activeDec 29, 1998
other section · miscellaneous violations
repair heater in room #622 (heater is leaking on to carpet ) sfhc 701.
Page 4 of 5
← PrevNext →