not activeNov 8, 2013
plumbing and electrical section · provide electrical permit (90.25 ec)
you are required to obtain an electrical permit to correct this violation. apply for a electrical permit along with a copy of this notice of violation and reference the complaint number. the electrical inspector must perform periodic and final inspections and sign the job card, before the housing inspector can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the re-inspection day.
not activeNov 8, 2013
plumbing and electrical section · provide plumbing permit (103.1.1 pc)
you are required to obtain a building permit to correct this violation. apply for a building permit along with a copy of this notice of violation and reference the complaint number. the building inspector must perform periodic and final inspections and sign the job card, before the housing inspector can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the re-inspection day.
not activeNov 8, 2013
plumbing and electrical section · repair electrical outlet (1001e hc)
there are a number of junction boxes in the basenment that have been tampered with since their last electrical inspection. covers are off and wires are proud of their junction boxes. wiring is to be corrected. do not close up these boxes until they have been ionspected. secure permits which include for rough electrical inspection and final inspection to insure that wiring in these areas meets current electrical code.
not activeNov 8, 2013
building section · building permit required (301 hc)
you are required to obtain a building permit to correct this violation. apply for a building permit along with a copy of this notice of violation and reference the complaint number. the building inspector must perform periodic and final inspections and sign the job card, before the housing inspector can abate this violation. present the signed job card indicating that work is complete to the housing inspector on the re-inspection day.
not activeNov 8, 2013
building section · replace the damaged ceilings (1001 b, d hc)
remove the marked areas of ceiling that have sewage stains to include all damage, miscellaneous patches of drywall and contaminated plaster. the replacement of this surface involves a fire rated assembly that shall be replaced by a licensed contractor and inspected by a building inspector through the department of building inspection's permit process.
not activeNov 8, 2013
other section · inspector comments
it is the property owner's responsibility to be present or direct his/ her representative to attend, the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/ or to provide access to all areas cited within this notice. provide all tenants with notification as required by california civil code section 1954 san francisco housing code section 303 (b), if any dwelling, apartment units or guest rooms are to be accessed during the re-inspection. important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. please review the attached "notice of violation warnings" for information regarding failure to comply with this notice. all open notices of violation will be re-inspected at this time.
not activeNov 8, 2013
plumbing and electrical section · remove leaking pipe (1001 f, hc)
also in this same room, locate the source of the leak in the 8" abandon line penetrating the ceiling. correct the problem and remove the remaining portion of abandon pipe to elimnate future problems.
not activeNov 8, 2013
building section · this notice includes violations for the areas noted.
unless otherwise noted, all violation were witnessed at the verona hotel, 317 leavenworth street, in the basement.
not activeNov 8, 2013
plumbing and electrical section · repair deteriorated drainage pipes (1001f hc)
cap the open end or remove the remaining section of second abandon 8" line.
not activeNov 8, 2013
sanitation section · eliminate rodent infestation (1001b, 1306 hc)
there is substantial evidence of rodents in the basement. perform rodent proofing as required. cover/seal all openings. due to the large gapping in the sidewalk access point it will be necessary to provide traps. provide regular pest control by an industry professional. provide a maintenance schedule at the time of re-inspection.
not activeNov 8, 2013
plumbing and electrical section · repair deteriorated drainage pipes(1001f hc)
moving from this main room one room north and one room west, repair the 2" copper p trap leaking from above.
not activeNov 8, 2013
building section · reinforce floor framing (1001(3)hc)
there is a framed opening that has been covered with a subfloor without the benefit of supporting framing below. once the contaminated drywall and plaster have been removed the entire floor diaphragm is to be reframed in an approved manner to sufficiently carry the imposed loads it will be subjected to in ordinary use.
not activeNov 8, 2013
plumbing and electrical section · repair leaking pipes (1001 f, hc)
the two sections of 3" soil line that penetrate the ceiling in the south east corner of the building where eddy street meets leavenworth are fatigued. the lead and oakum sections are draining onto the floor. the clean out has a temporary cap. all sections of 3" and 4" lines of lead and oakum construction shall be replaced in an approved manner with permits.
not activeNov 8, 2013
building section · sanitation (1306 hc)
all concrete and brick walls and floor areas involved in the basement shall be cleaned, sanitized from the filth and raw sewage evident from deferred maintenance and faulty piping.
not activeJun 20, 2000
fire section · recharge all fire extinguishers (905, 1001(m) hc)
not activeJun 20, 2000
plumbing and electrical section · water heaters
secure water heaters with metal straps.
not activeJun 20, 2000
other section · provide shutoff tool for gas utility shutoff (712 hc)
not activeJun 20, 2000
plumbing and electrical section · recharge all fire extinguishers (905, 1001(m) hc)
not activeJun 20, 2000
other section · post enclosed gas meter instructional diagram in a public area. (712 hc)