1040 BUSH ST

Nob Hill · San Francisco, CA · Parcel 0276013 · Last violation Jun 26, 2024 · Last complaint Oct 15, 2025

NeighborhoodNob Hill
More violations than 90% of nearby buildings
More violations than 90% of buildings and more complaints than 97% of buildings in Nob Hill. Size-normalized against residential buildings in the neighborhood.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 0 violations · 10 complaints
'21'25ViolationsComplaints
Severityⓘopen violations
1 open fire-safety violation
Active Notices of Violation issued by the Department of Building Inspection.
Open fire-safety violations1
Open lead violations0
311 Housing Complaints
Total complaints since 2010
83
5 per year avg.↓ Down 64% in the last 2 years (10 vs 28 prior 2 yrs)
Reported issues
10
Heatⓘ6
Leadⓘ0
Pestsⓘ28
Dept. of Building Inspection Violations
Total violations since 1999
114
4 per year avg.↓ Down 100% in the last 2 years (0 vs 10 prior 2 yrs)
Open violations
19
Fire safetyⓘ1
Leadⓘ0

Top violation categories

5 yrsAll time
other section8 violations
building section8 violations
interior surfaces section7 violations
Unknown3 violations
plumbing and electrical section3 violations
fire section1 violations
smoke detection section1 violations

Top complaint types

5 yrsAll time
Infestation Rodent Insect12 complaints
Bathroom8 complaints
Clutter Hoarder Unit Interior Storage7 complaints
Mold And Mildew6 complaints
Heat Lack Of Heat5 complaints
Paint Peeling3 complaints
Elevators Everthing Else3 complaints
Kitchen Community2 complaints
Infestation Bed Bugs2 complaints
Plumbing Broken Leaking2 complaints
Doors Windows Broken Defective1 complaints
General Maintenance Not In List Above1 complaints
Garbage Receptacles1 complaints
Deck Stairs Handrails1 complaints
Hide violations (114) ↑See complaints (83) →

Violation log

114 DBI violations

AllOpenClosed
StatusFiledCategoryItemNOV Item Description
OpenJan 30, 2017plumbing and electrical sectioncap the waste line 1001f sfhcthere is an unused standpipe in the laundry room, left uncapped. provide a end cap to the unused line.
See something wrong? File a complaint with SF 311
OpenJan 30, 2017interior surfaces sectionrepair damaged walls and ceiling 1001 b13, d, 1301 sfhcthe walls in the top floor recreation room have cracked, blistered and peeled to leave paint debris on floors and sills throughout. remove all damaged and blistered material and replace, plaster, prep, prime and paint to complete these repairs.
OpenJan 30, 2017building sectionprovide carbon monoxide detectors 420 cbc provide smoke detectors 908, 911 sfhc, 907.2.11 sfbcprovide carbon monoxide detectors laid out per the san francisco building code section 420. there shall be one unit in each guest room within the immediate floor and each adjacent floor, above and below a gas burning appliance to include stoves, dryers, furnaces, water heaters and boilers. install smoke detectors as required by the san francisco building code. a self-certification form has been included for your convenience. provide completed form at inspection or return by mail to: department of building inspection housing division, c. grady 1660 mission street, 6th floor san francisco, ca 94103
OpenJan 30, 2017plumbing and electrical sectionprovide light bulbs 1001e sfhcthere are light bulbs missing from the motion sensored light fixtures on the roof, around the roof deck. provide light bulbs and insure the fixtures are operating.
OpenJan 30, 2017sanitation sectionrepair the water fountain 1001k, l sfhc, 602.6 adathe water flow at the basement level water fountain has a limited flow rate. water fountains should provide a flow of water 4 inches in height. service the water fountain to increase the water flow.
OpenJan 30, 2017sanitation sectionrepair the plumbing in the basement level bathrooms 1001d, l sfhcthere are 2 basement level bathrooms closed and locked, labelled "out of service". provide appropriate repairs to these bathrooms to return them back to service.
OpenJan 30, 2017building sectionrework paint to allow operation of the window 1001b7, 8, d sfhcmany of the bathroom windows are painted shut, trapping steam after showering/bathing and presenting an environment for mold growth. rework the paint to release the window sashes. ensure that the sash and frame provide smooth and easy operation and a weather tight condition with a working latch. window is to remain open at any desired position with the balance of a counter weight. or secure a building permit and provide mechanical ventilation.
OpenJan 30, 2017fire sectionmalfunctioning appliance - repair auxiliary lighting 504g, 1001e & l sfhc, 1011.6.3 sfbcmany of the auxiliary lighting fixtures with the green exit indicators in the halls and rear stairs fail testing. replace the batteries in the auxiliary lighting system or replace the lighting fixtures. if the fixtures are replaced the new units should have illuminated directional exit indications.
OpenJan 30, 2017other sectioninspector commentsimportant note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
OpenJan 30, 2017plumbing and electrical sectionmake necessary repairs to tub faucet 1001 sfhcin the top floor bathroom there is a tub faucet with a leak at the tile wall that has been repaired with aluminum foil type duct tape. remove the duct tape and provide appropriate repairs, leaving the faucet in functioning condition without tape.
OpenJan 30, 2017plumbing and electrical sectionrepair deteriorated drainage pipes at exterior 1001f sfhcvisible from unit 217, across the light well there is a vent pipe with obvious breaks coming from the second floor bathroom. replace the broken pipe. *** this item will require plumbing permits
OpenJan 30, 2017building sectionthis notice includes violations for the areas noted.this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 1040 bush street in the common areas. this was a complaint generated routine inspection initiated by complaint number 201759533.
OpenJan 30, 2017building sectionrepair the roof access door 706 & 805 & 912 sfhcthe roof access door a the rear stairs is delaminating and falling appart at the bottom. exit doors shall be a minimum one-and-three-eighths inch solid wood core or approved equal. doors and jambs shall be tight fitting, in good condition and self-closing. roof access doors shall be covered on the roof side with galvanized steel or otherwise weather proof metal. roof access doors will be installed with a primary locking device with a minimum one half inch dead latch and shall be operable from the interior without a key and no special knowledge or effort shall be required. the roof access door may be locked from the inside with a movable bolt. repair the exit door to the roof.
OpenJan 30, 2017building sectionreplace window sash cord 1001d, h, 708 sfhcmany of the windows in the bathrooms and other common areas have broken or missing sash cords. these are an instrumental part of the window operating properly. replace the missing/broken sash cords in all common area windows to include the recreation room, hallways, bath rooms, laundry room and kitchen.
OpenJan 30, 2017interior surfaces sectionprovide a sweep on entry door 1001h sfhcthe guest room entry door to unit 217 is weather stripped on 3 sides. complete the installation by adding a sweep to the bottom of the door.
OpenJan 30, 2017building sectionrepair window hardware 1001b, d sfhcin the common area hallways, casement style windows were found to have broken handles and cranks, limiting their use as natural ventilation. repair the window handles and cranks on the casement style windows.
not activeDec 14, 2016other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. important note: due to the violations noted, this property is defined as a nuisance per sec. 1001-d of the sfhc. please review the attached "notice of violation warnings" for information regarding failure to comply with this notice.
not activeDec 14, 2016interior surfaces sectioneliminate mold (1002d, 1306 hc)eliminate the mold located on the interior surface of the exterior masonry wall located in #307.
not activeDec 14, 2016interior surfaces sectionrepair damaged ceilings (1001b,h hc)locate and repair the source of the moisture causing mold in #307.
not activeApr 7, 2016———
not activeApr 7, 2016———
not activeJan 13, 2016building sectionthis notice includes violations for the areas noted.this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 1040 bush street, unit 217.
not activeJan 13, 2016building sectionrepair door and frame 1001d, b13 sfhcthe guest room entry door is hanging from the top hinge and does not self close as intended. the screws in the top hinge are tearing out from the door and jamb. doors and jambs shall be tight fitting, in good condition, self-closing and self-latching. conduct repair to meet these requirements.
not activeJan 13, 2016building sectionpaint the window 1301 sfhconce repairs on this window are complete prep, prime and paint to complete the repair.
not activeJan 13, 2016building sectionlead warning (continued)information packets are available at the housing division of the san francisco department of building inspection, 1660 mission street at the 6th floor counter. you can contact the san francisco childhood lead poisoning prevention program at: (415) 252-3800 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by that dust. ordinance #446-97.
not activeJan 13, 2016other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. 303 sfhc if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeJan 13, 2016building sectionrepair window sash frame 1001d, h, 708 sfhcthe window in this unit is showing signs of rot and deterioration. the paint is severly peeling. repair or replace the window sash frames to eliminate any rot and insure that glass panels are secured appropriately with glazer's putty or other approved method providing a weather proof condition. ensure that the sash and frame provide smooth and easy operation and a weather tight condition with a working latch. window is to remain open at any desired position with the balance of a counter weight.
not activeJan 13, 2016plumbing and electrical sectionrepair lightswitch 1001e sfhcthe light switch to this unit emits an audible crackle when switched. repair or replace the light switch.
not activeJan 13, 2016building sectionlead warningdisturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal: follow the approved methods of the epa rrp or other similar lead abatement training. this structure was constructed prior to 1979 and therefore presumed to contain lead. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3426, sfbc)
not activeSep 19, 2014———
not activeSep 19, 2014———
not activeMar 12, 2014building sectionthis notice includes violations for the areas noted.these violations are in the bathrooms in the common areas of the building.
not activeMar 12, 2014other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner can not attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeMar 12, 2014building sectioninstall grab bars in all common area water closets, lavatories and bathing facilities to comply with ordinance 029-13 (301, 505(j), 1002(g) hc).building permit is required.
not activeApr 6, 2012building sectionrepair window sash cords (1001(h) hc)repair the numerous broken sash cords in the bathrooms of every floor.
not activeApr 6, 2012other sectiondue to the violations noted, this property is considered a nuisance, as defined by sec. 1001 (d) hc. it is the owner's responsibility to attend the reinspection scheduled below (or send a representative) and provide access to the areas cited. if this is not possible, the owner must obtain other inspections until compliance is confirmed.—
not activeFeb 22, 2010———
not activeFeb 22, 2010———
not activeAug 7, 2007other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeAug 7, 2007plumbing and electrical sectionmake necessary repairs to tub/shower (1001 hc)replace the missing shower head and seat in the handicap shower on the 3rd floor.
not activeMay 15, 2006building sectionthis notice includes violations for the areas noted.1040 bush st. *heat sweep inspection *routine inspection of the (common area) building sec.(303 a s.f.h.c.)
not activeMay 15, 2006smoke detection sectioncentral alarm system (909 hc)provide certification: reminder central alarm panel are required to be cerifed annually by a licenced contractor and post ceritification on the panel door (sec 908,909,(b) s.f.h.c.
not activeMay 15, 2006other sectionheat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)heat sweep inspection: a random room inspection was performed (tenants were present at the time of initial inspection) guest rooms are provided with steam heater (radiator) boiler is located on the ground fl. adjacent to the residential kitchen
not activeMay 15, 2006other sectioninspector commentsit is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as schedule on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with the inspector, and provide all tenants with notification as required by california civil code section 1954(san francisco housing code section 303(b),if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeMay 15, 2006fire sectionremove egress obstruction at (801,1001(l) hc)all storage from the ground level exterior side passageway to the street, (this area must remain clear and clean at all times.)
not activeMay 15, 2006fire sectionmaintain fire escape drop ladder in working condition (sec 908 hc)note: property manager, owner or the owner's agent needs to provide a proof of the workability of the fire escape ladders. non-working fire escape ladder is a life safety hazard and must be corrected immediately. provide a written report from a qualified service company or licenced contractor stating that all parts and cables have tested and are functional or contact the housing inspector (within 30 days) to witness lowering the ladder in person. **reminder**all manufacturers recommend that the fire escape drop ladder be maintained and serviced annually, particularly the cable and all moving parts. lubricate and drop the ladder at least once a year.
not activeMay 15, 2006other sectionprovide non-tamperable temp.-sensing device with a + to -1 1/2 degree f. (.8 degrees c.) tol., centrally located in bldg in habitable rm (not mgr or owner's) to which heat is provided, occupied or not (701c hc)relocate the existing thermostat (located in the office). upon reinspection: provide access to the new location of the thermostat. (habitable room) note: thermostat shall be installed at point of three feet above the floor.
not activeDec 13, 2002building sectionfailure to file for necessary permits in order to comply with the residential hotel sprinkler ordinance #170-02.submit a building permit application with plans to the department of building inspection within 15 days of this notice to comply with the residential hotel sprinkler ordinance #170-02, section 904 s.f.h.c.
not activeJan 15, 2002———
not activeMar 13, 2001building sectionlack of handrails along rear stairs connecting cafeteria with rear yard.install two handrails to rear interior stairs.1001hc.
OpenJan 30, 2017
plumbing and electrical section · cap the waste line 1001f sfhc
there is an unused standpipe in the laundry room, left uncapped. provide a end cap to the unused line.
OpenJan 30, 2017
interior surfaces section · repair damaged walls and ceiling 1001 b13, d, 1301 sfhc
the walls in the top floor recreation room have cracked, blistered and peeled to leave paint debris on floors and sills throughout. remove all damaged and blistered material and replace, plaster, prep, prime and paint to complete these repairs.
OpenJan 30, 2017
building section · provide carbon monoxide detectors 420 cbc provide smoke detectors 908, 911 sfhc, 907.2.11 sfbc
provide carbon monoxide detectors laid out per the san francisco building code section 420. there shall be one unit in each guest room within the immediate floor and each adjacent floor, above and below a gas burning appliance to include stoves, dryers, furnaces, water heaters and boilers. install smoke detectors as required by the san francisco building code. a self-certification form has been included for your convenience. provide completed form at inspection or return by mail to: department of building inspection housing division, c. grady 1660 mission street, 6th floor san francisco, ca 94103
OpenJan 30, 2017
plumbing and electrical section · provide light bulbs 1001e sfhc
there are light bulbs missing from the motion sensored light fixtures on the roof, around the roof deck. provide light bulbs and insure the fixtures are operating.
OpenJan 30, 2017
sanitation section · repair the water fountain 1001k, l sfhc, 602.6 ada
the water flow at the basement level water fountain has a limited flow rate. water fountains should provide a flow of water 4 inches in height. service the water fountain to increase the water flow.
OpenJan 30, 2017
sanitation section · repair the plumbing in the basement level bathrooms 1001d, l sfhc
there are 2 basement level bathrooms closed and locked, labelled "out of service". provide appropriate repairs to these bathrooms to return them back to service.
OpenJan 30, 2017
building section · rework paint to allow operation of the window 1001b7, 8, d sfhc
many of the bathroom windows are painted shut, trapping steam after showering/bathing and presenting an environment for mold growth. rework the paint to release the window sashes. ensure that the sash and frame provide smooth and easy operation and a weather tight condition with a working latch. window is to remain open at any desired position with the balance of a counter weight. or secure a building permit and provide mechanical ventilation.
OpenJan 30, 2017
fire section · malfunctioning appliance - repair auxiliary lighting 504g, 1001e & l sfhc, 1011.6.3 sfbc
many of the auxiliary lighting fixtures with the green exit indicators in the halls and rear stairs fail testing. replace the batteries in the auxiliary lighting system or replace the lighting fixtures. if the fixtures are replaced the new units should have illuminated directional exit indications.
OpenJan 30, 2017
other section · inspector comments
important note: due to the nature of this violation, this property has been defined as a nuisance per section 1001-d of the san francisco housing code. it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
OpenJan 30, 2017
plumbing and electrical section · make necessary repairs to tub faucet 1001 sfhc
in the top floor bathroom there is a tub faucet with a leak at the tile wall that has been repaired with aluminum foil type duct tape. remove the duct tape and provide appropriate repairs, leaving the faucet in functioning condition without tape.
OpenJan 30, 2017
plumbing and electrical section · repair deteriorated drainage pipes at exterior 1001f sfhc
visible from unit 217, across the light well there is a vent pipe with obvious breaks coming from the second floor bathroom. replace the broken pipe. *** this item will require plumbing permits
OpenJan 30, 2017
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 1040 bush street in the common areas. this was a complaint generated routine inspection initiated by complaint number 201759533.
OpenJan 30, 2017
building section · repair the roof access door 706 & 805 & 912 sfhc
the roof access door a the rear stairs is delaminating and falling appart at the bottom. exit doors shall be a minimum one-and-three-eighths inch solid wood core or approved equal. doors and jambs shall be tight fitting, in good condition and self-closing. roof access doors shall be covered on the roof side with galvanized steel or otherwise weather proof metal. roof access doors will be installed with a primary locking device with a minimum one half inch dead latch and shall be operable from the interior without a key and no special knowledge or effort shall be required. the roof access door may be locked from the inside with a movable bolt. repair the exit door to the roof.
OpenJan 30, 2017
building section · replace window sash cord 1001d, h, 708 sfhc
many of the windows in the bathrooms and other common areas have broken or missing sash cords. these are an instrumental part of the window operating properly. replace the missing/broken sash cords in all common area windows to include the recreation room, hallways, bath rooms, laundry room and kitchen.
OpenJan 30, 2017
interior surfaces section · provide a sweep on entry door 1001h sfhc
the guest room entry door to unit 217 is weather stripped on 3 sides. complete the installation by adding a sweep to the bottom of the door.
OpenJan 30, 2017
building section · repair window hardware 1001b, d sfhc
in the common area hallways, casement style windows were found to have broken handles and cranks, limiting their use as natural ventilation. repair the window handles and cranks on the casement style windows.
not activeDec 14, 2016
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection. important note: due to the violations noted, this property is defined as a nuisance per sec. 1001-d of the sfhc. please review the attached "notice of violation warnings" for information regarding failure to comply with this notice.
not activeDec 14, 2016
interior surfaces section · eliminate mold (1002d, 1306 hc)
eliminate the mold located on the interior surface of the exterior masonry wall located in #307.
not activeDec 14, 2016
interior surfaces section · repair damaged ceilings (1001b,h hc)
locate and repair the source of the moisture causing mold in #307.
not activeApr 7, 2016
—
not activeApr 7, 2016
—
not activeJan 13, 2016
building section · this notice includes violations for the areas noted.
this notice includes violations of the san francisco housing code. unless noted otherwise, all violations were observed on the date of inspection at 1040 bush street, unit 217.
not activeJan 13, 2016
building section · repair door and frame 1001d, b13 sfhc
the guest room entry door is hanging from the top hinge and does not self close as intended. the screws in the top hinge are tearing out from the door and jamb. doors and jambs shall be tight fitting, in good condition, self-closing and self-latching. conduct repair to meet these requirements.
not activeJan 13, 2016
building section · paint the window 1301 sfhc
once repairs on this window are complete prep, prime and paint to complete the repair.
not activeJan 13, 2016
building section · lead warning (continued)
information packets are available at the housing division of the san francisco department of building inspection, 1660 mission street at the 6th floor counter. you can contact the san francisco childhood lead poisoning prevention program at: (415) 252-3800 for free advice. if you cause lead dust to be created, you could be liable for any illness caused by that dust. ordinance #446-97.
not activeJan 13, 2016
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the re-inspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. 303 sfhc if the property owner cannot attend the scheduled re-inspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the re-inspection.
not activeJan 13, 2016
building section · repair window sash frame 1001d, h, 708 sfhc
the window in this unit is showing signs of rot and deterioration. the paint is severly peeling. repair or replace the window sash frames to eliminate any rot and insure that glass panels are secured appropriately with glazer's putty or other approved method providing a weather proof condition. ensure that the sash and frame provide smooth and easy operation and a weather tight condition with a working latch. window is to remain open at any desired position with the balance of a counter weight.
not activeJan 13, 2016
plumbing and electrical section · repair lightswitch 1001e sfhc
the light switch to this unit emits an audible crackle when switched. repair or replace the light switch.
not activeJan 13, 2016
building section · lead warning
disturbing lead based paint can be extremely dangerous to dwelling occupants and visitors, particularly to young children, pregnant women, pets, and to people performing work on the premises. for interior or exterior paint removal: follow the approved methods of the epa rrp or other similar lead abatement training. this structure was constructed prior to 1979 and therefore presumed to contain lead. if you are unsure whether the paint is leaded, you should test it prior to performing any work. if the paint is found to contain lead, you should consult with an expert about appropriate procedures. proper containment and 3-day notification is required for exterior jobs of more than 10 sq.ft. (sec.3426, sfbc)
not activeSep 19, 2014
—
not activeSep 19, 2014
—
not activeMar 12, 2014
building section · this notice includes violations for the areas noted.
these violations are in the bathrooms in the common areas of the building.
not activeMar 12, 2014
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner can not attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeMar 12, 2014
building section · install grab bars in all common area water closets, lavatories and bathing facilities to comply with ordinance 029-13 (301, 505(j), 1002(g) hc).
building permit is required.
not activeApr 6, 2012
building section · repair window sash cords (1001(h) hc)
repair the numerous broken sash cords in the bathrooms of every floor.
not activeApr 6, 2012
other section · due to the violations noted, this property is considered a nuisance, as defined by sec. 1001 (d) hc. it is the owner's responsibility to attend the reinspection scheduled below (or send a representative) and provide access to the areas cited. if this is not possible, the owner must obtain other inspections until compliance is confirmed.
not activeFeb 22, 2010
—
not activeFeb 22, 2010
—
not activeAug 7, 2007
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeAug 7, 2007
plumbing and electrical section · make necessary repairs to tub/shower (1001 hc)
replace the missing shower head and seat in the handicap shower on the 3rd floor.
not activeMay 15, 2006
building section · this notice includes violations for the areas noted.
1040 bush st. *heat sweep inspection *routine inspection of the (common area) building sec.(303 a s.f.h.c.)
not activeMay 15, 2006
smoke detection section · central alarm system (909 hc)
provide certification: reminder central alarm panel are required to be cerifed annually by a licenced contractor and post ceritification on the panel door (sec 908,909,(b) s.f.h.c.
not activeMay 15, 2006
other section · heat to each occupied habitable room for 13 hrs between 5:00 a.m. and 11:00 a.m. and between 3:00 p.m. and 10:00 p.m. capable to maintaining a min. room temp. of 68 degrees f. (20 degrees c.). (701c hc)
heat sweep inspection: a random room inspection was performed (tenants were present at the time of initial inspection) guest rooms are provided with steam heater (radiator) boiler is located on the ground fl. adjacent to the residential kitchen
not activeMay 15, 2006
other section · inspector comments
it is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as schedule on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with the inspector, and provide all tenants with notification as required by california civil code section 1954(san francisco housing code section 303(b),if any dwellings, apartment units or guest rooms are to be accessed during the reinspection.
not activeMay 15, 2006
fire section · remove egress obstruction at (801,1001(l) hc)
all storage from the ground level exterior side passageway to the street, (this area must remain clear and clean at all times.)
not activeMay 15, 2006
fire section · maintain fire escape drop ladder in working condition (sec 908 hc)
note: property manager, owner or the owner's agent needs to provide a proof of the workability of the fire escape ladders. non-working fire escape ladder is a life safety hazard and must be corrected immediately. provide a written report from a qualified service company or licenced contractor stating that all parts and cables have tested and are functional or contact the housing inspector (within 30 days) to witness lowering the ladder in person. **reminder**all manufacturers recommend that the fire escape drop ladder be maintained and serviced annually, particularly the cable and all moving parts. lubricate and drop the ladder at least once a year.
not activeMay 15, 2006
other section · provide non-tamperable temp.-sensing device with a + to -1 1/2 degree f. (.8 degrees c.) tol., centrally located in bldg in habitable rm (not mgr or owner's) to which heat is provided, occupied or not (701c hc)
relocate the existing thermostat (located in the office). upon reinspection: provide access to the new location of the thermostat. (habitable room) note: thermostat shall be installed at point of three feet above the floor.
not activeDec 13, 2002
building section · failure to file for necessary permits in order to comply with the residential hotel sprinkler ordinance #170-02.
submit a building permit application with plans to the department of building inspection within 15 days of this notice to comply with the residential hotel sprinkler ordinance #170-02, section 904 s.f.h.c.
not activeJan 15, 2002
—
not activeMar 13, 2001
building section · lack of handrails along rear stairs connecting cafeteria with rear yard.
install two handrails to rear interior stairs.1001hc.