stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

102 MAPLE AVENUE

Staten Island · ZIP 10302 · BIN 5025407 · Port Richmond · Last violation Mar 30, 2026 · Last complaint Feb 15, 2026

NeighborhoodPort Richmond
More violations than 100% of nearby buildings
More violations than 100% of buildings and more complaints than 100% of buildings in Port Richmond. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 125 violations · 95 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
14 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous14Class Bhazardous115
Housing Preservation & Development Violations
Total violations since 2022
165
33 per year avg.↑ Up 279% in the last 2 years (125 vs 33 prior 2 yrs)
Open violations
145
Class C (immed. haz.)ⓘ14
Class B (hazardous)ⓘ115
Rent-impairingⓘ0
Open violation ages
▪ 30–90 days1% (1)
▪ 3–12 months30% (42)
▪ 1–3 years61% (87)
▪ 3+ years8% (12)
Housing Preservation & Development Complaints
Total complaints since 2021
219
37 per year avg.↓ Down 17% in the last 2 years (95 vs 115 prior 2 yrs)
Complaint Resolution
No access23%Violation issued19%No violation56%Phone resolved1%Other0%(219)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ70 violations
Water Supplyⓘ31 violations
Extermination & Rodent Eradicationⓘ22 violations
Cleaningⓘ10 violations
Carbon Monoxide Detecting Devicesⓘ7 violations
Sewers And Drainageⓘ5 violations
Paintingⓘ4 violations
Artificial Lightingⓘ3 violations
Top complaint groupsⓘ
5 yrsAll time
Bldg maintenanceⓘ51 complaints
Water & plumbingⓘ50 complaints
Mold & pestsⓘ43 complaints
Appliancesⓘ22 complaints
Heat / hot waterⓘ11 complaints
Safety & fireⓘ10 complaints
Electricalⓘ8 complaints
Outdoor / structuralⓘ2 complaints
Hide violations ↑See complaints →

Violation log

116 violations · Class B

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Prior 4 yr.
Immed. Emergency10%1%
Emergency55%45%
Non-Emergency34%53%
(29)
(187)
Issued
Description
Class BOpen2Sep 29, 2023INADEQUATE COLD WATER · WATER SUPPLY§ 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen2Sep 29, 2023INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen2Sep 29, 2023REPLACE · MAINTENANCE§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING WOOD DOORS AT WALL CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen2Sep 29, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT FLOOR IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen2Sep 29, 2023REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen2Sep 29, 2023REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE METAL COVER ON BASEBOARD RADIATOR AT WEST WALL IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen2Sep 29, 2023REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE ON UPPER SASH WINDOW AT NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen2Sep 29, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKET SEAL AROUND REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen2Sep 29, 2023REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING IN THE ENTRANCE LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen2Mar 3, 2023REPAIR · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE 1ST WOOD DOOR FROM NORTH AT EAST. IN THE FOYER LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen2Mar 3, 2023REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen1STFLODec 14, 2022LEAKY ROOF · MAINTENANCE§ 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen1STFLODec 13, 2022REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen1STFLODec 13, 2022REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUB-FLOOR IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed1STFLODec 13, 2022REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK .. CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen1STFLODec 13, 2022REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK .. CEILING IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Sep 29, 2023Apt 2
INADEQUATE COLD WATER · WATER SUPPLY
§ 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Sep 29, 2023Apt 2
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Sep 29, 2023Apt 2
REPLACE · MAINTENANCE
§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING WOOD DOORS AT WALL CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Sep 29, 2023Apt 2
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT FLOOR IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Sep 29, 2023Apt 2
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Sep 29, 2023Apt 2
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE METAL COVER ON BASEBOARD RADIATOR AT WEST WALL IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Sep 29, 2023Apt 2
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE ON UPPER SASH WINDOW AT NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Sep 29, 2023Apt 2
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKET SEAL AROUND REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Sep 29, 2023Apt 2
REPAIR/ABATE UNSAFE WIRES · ARTIFICIAL LIGHTING
§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING IN THE ENTRANCE LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Mar 3, 2023Apt 2
REPAIR · MAINTENANCE
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE 1ST WOOD DOOR FROM NORTH AT EAST. IN THE FOYER LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Mar 3, 2023Apt 2
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Dec 14, 2022Apt 1STFLO
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Dec 13, 2022Apt 1STFLO
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Dec 13, 2022Apt 1STFLO
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUB-FLOOR IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed
Dec 13, 2022Apt 1STFLO
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK .. CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Dec 13, 2022Apt 1STFLO
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK .. CEILING IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 1STFLO, 1st STORY, 1st APARTMENT FROM NORTH AT EAST