Class BClosedRENT IMPAIRING
Aug 19, 2015Apt 14K
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CELING IN THE CLOSET AT EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 14K, 14th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Aug 19, 2015Apt 14K
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS AT CLOSET ON EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 14K, 14th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Mar 16, 2015Apt 7C
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING APPROX. 1SQ.FT. IN THE BATHROOM LOCATED AT APT 7C, 7th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 9, 2015Apt 12B
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 12B, 12th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Mar 9, 2015Apt 12B
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 12B, 12th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Feb 17, 2015Apt 5H
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 6th APARTMENT FROM NORTH AT EAST
Class BClosed
Feb 17, 2015Apt 5H
NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 6th APARTMENT FROM NORTH AT EAST
Class BClosed
Dec 24, 2014Apt 1C
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE LOCATED AT APT 1C, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed
Dec 24, 2014Apt 1C
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE LOCATED AT APT 1C, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed
Sep 10, 2014Apt 6H
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE BATHROOM LOCATED AT APT 6H, 6th STORY, 6th APARTMENT FROM NORTH AT EAST
Class BClosed
May 29, 2014Apt 14K
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... WALLS & CEILING AT CLOSET IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 14K, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
May 29, 2014Apt 14K
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING AT CLOSET IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 14K, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosedRENT IMPAIRING
May 29, 2014Apt 14K
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT CLOSET IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 14K, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
May 22, 2014Apt L1
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE LIVING-ROOM LOCATED AT APT L1, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
May 22, 2014Apt L1
NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT L1, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
May 22, 2014Apt L1
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS MISSING. IN THE ENTIRE APARTMENT LOCATED AT APT L1, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
May 9, 2014Apt 1K
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASH BASIN IN THE BATHROOM LOCATED AT APT 1K, 1st STORY
Class BClosed
May 9, 2014Apt 1K
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD BASE CABINET IN THE ENTIRE APARTMENT LOCATED AT APT 1K, 1st STORY
Class BClosed
May 9, 2014Apt 1K
REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AND SINK IN THE ENTIRE APARTMENT LOCATED AT APT 1K, 1st STORY
Class BClosed
May 9, 2014Apt 1K
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 1K, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
May 9, 2014Apt 1K
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 1K, 1st STORY
Class BClosed
May 9, 2014Apt 1K
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT EAST WALL IN THE BATHROOM LOCATED AT APT 1K, 1st STORY
Class BClosed
Mar 20, 2014Apt 5H
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 6th APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 20, 2014Apt 5H
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ... IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 6th APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 20, 2014Apt 5H
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SHOWER BODY IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 6th APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 20, 2014Apt 5H
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 5H, 5th STORY, 6th APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 20, 2014Apt 5H
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 6th APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 20, 2014Apt 5H
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 5H, 5th STORY, 6th APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 18, 2013Apt L3
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT L3
Class BClosed
Mar 4, 2013Apt 14D
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... MILDEW AT CEILING. APPOX. 4 SQ.FT. IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 14D, 13th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 4, 2013Apt 14D
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WINDOW SASH IN THE ENTIRE APARTMENT LOCATED AT APT 14D, 13th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 4, 2013Apt 14D
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 14D, 13th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 4, 2013Apt 14D
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 14D, 13th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Mar 4, 2013Apt 14D
NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 14D, 13th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Jan 17, 2013Apt 5J
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jan 17, 2013Apt 5J
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 5J, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Jun 26, 2012Apt 14K
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT CLOSET IN NORTHWEST ROOM LOCATED AT APT 14K, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Jun 26, 2012Apt 14K
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING AT CLOSET IN NORTHWEST ROOM LOCATED AT APT 14K, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Feb 9, 2012Apt 14K
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING 1ST ROOM FROM NORTH LOCATED AT APT 14K, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosedRENT IMPAIRING
Feb 9, 2012Apt 14K
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CLOSET 1ST ROOM FROM NORTH LOCATED AT APT 14K, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Sep 7, 2011Apt L3
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT L3, 1st STORY, APARTMENT AT EAST
Class BClosed
Sep 7, 2011Apt L3
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE FOYER LOCATED AT APT L3, 1st STORY, APARTMENT AT EAST
Class BClosed
Sep 7, 2011Apt L3
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT L3, 1st STORY, APARTMENT AT EAST
Class BClosed
Sep 7, 2011
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WIRE GLASS ON DOOR AT CELLAR PUBLIC HALL TO NORTH YARD
Class BClosed
Sep 7, 2011Apt L3
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT L3, 1st STORY, APARTMENT AT EAST
Class BClosed
Sep 7, 2011Apt 14K
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS AT CLOSET IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 14K, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Sep 7, 2011Apt L3
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT L3, 1st STORY, APARTMENT AT EAST
Class BClosedRENT IMPAIRING
Sep 7, 2011Apt 14K
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CLOSET CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 14K, 13th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Sep 7, 2011Apt L3
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT L3, 1st STORY, APARTMENT AT EAST
Class BClosed
Aug 3, 2011Apt L3
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT SUB-CELLAR-APT L3, 1st SUB-CELLAR-APT FROM NORTH AT EAST