stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

99-77 1 STREET

Queens · ZIP 11694 · BIN 4000000 · Rockaway Beach-Arverne-Edgemere · Last violation Jun 11, 2026 · Last complaint Jun 25, 2026

NeighborhoodRockaway Beach-Arverne-Edgemere
More violations than 100% of nearby buildings
More violations than 100% of buildings and more complaints than 100% of buildings in Rockaway Beach-Arverne-Edgemere. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 763 violations · 1175 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
294 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous294Class Bhazardous739
Housing Preservation & Development Violations
Total violations since 1989
4,551
120 per year avg.↑ Up 108% in the last 2 years (763 vs 367 prior 2 yrs)
Open violations
1,735
Class C (immed. haz.)ⓘ294
Class B (hazardous)ⓘ739
Rent-impairingⓘ59
Housing Preservation & Development Complaints
Total complaints since 2003
5,918
247 per year avg.↑ Up 208% in the last 2 years (1,175 vs 382 prior 2 yrs)
Complaint Resolution
No access25%Violation issued18%No violation33%Phone resolved24%Other1%(5,894)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Filing: Bedbugsⓘ303 violations
Maintenanceⓘ248 violations
Posting/Signageⓘ165 violations
Egressⓘ156 violations
Heat And Hot Waterⓘ80 violations
Water Supplyⓘ60 violations
Carbon Monoxide Detecting Devicesⓘ58 violations
Annual Property Registrationⓘ38 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ497 complaints
Water & plumbingⓘ322 complaints
Mold & pestsⓘ270 complaints
Bldg maintenanceⓘ222 complaints
Electricalⓘ106 complaints
Appliancesⓘ70 complaints
Safety & fireⓘ45 complaints
Adminⓘ12 complaints
Elevatorⓘ2 complaints
Hide violations ↑See complaints →

Violation log

4,563 violations

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Open violation ages
▪ < 30 days1% (19)
▪ 30–90 days5% (77)
▪ 3–12 months7% (99)
▪ 1–3 years13% (188)
▪ 3+ years73% (1057)
Prior 4 yr.
Immed. Emergency7%5%
Emergency63%57%
Non-Emergency30%37%
(773)
(910)
Issued
Description
Class BClosed2RJan 25, 2006§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE SHOWER BODY VALVE HANDLE IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE SHOWER BODY VALVE HANDLE IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY
Class BClosed2RJan 25, 2006REMOVE VERMIN · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2018.4 ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY
Class BClosed2RJan 25, 2006REMOVE VERMIN · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2018.4 ABATE THE NUISANCE CONSISTING OF VERMIN BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY
Class BClosed2RJan 11, 2006REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS MISSING AT 2 STY APT 2R TENANT MR SANDOLAN. , SECTION '' ''
Class BClosed—Jan 11, 2006PROVIDE LIGHT - Not Less that 60 Watt incadescent · ARTIFICIAL LIGHTING§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION 2 STY PUBLIC HALL.
Class BClosed2LFJan 11, 2006REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING BATHROOM 2 STY APT 2LF. LOCATED AT APT 2LF
Class BClosed—Jan 11, 2006REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL AT BATHROOM 2 STY NORTHWEST APT.
Class BClosed—Jan 11, 2006REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK CLIPS AT TOP AND BOTTOM WINDOW SASHES AT NORTH ROOM 2 STY N ORTHWEST APT.
Class CClosed—Jan 11, 2006POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT OR NEAR MAILBOXES 1 STY PUBLIC HALL AND BOILER ROOM DOOR.
Class CClosed—Jan 11, 2006PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED CELLAR DOOR AT 1 STY PUBLIC HALL.
Class BClosed2RJan 11, 2006REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 2 STY EAST APT 2R MRS NICHOLAS. LOCATED AT APT 2R
Class CClosed2LJan 11, 2006ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF NO ELECTRIC SERVICE PROVIDED AT LIGHT FIXTURE AT 2 STY NORTHWEST APT 2L AS PER 27-2057 HMC ER1. LOCATED AT APT 2L
Class BClosed2LFJan 11, 2006REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE CEILING FRONT ROOM 2 STY APT 2LF. LOCATED AT APT 2LF
Class CClosed—Jan 11, 2006REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE LOOSE LEANING AND COLLAPSING BRICK WORK AT EAST PARAPET AT SOUTH CORNER BEHIND ORNAMENTAL ROOF CORNICE ER1.
Class BClosed2LFJan 11, 2006REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE TOP AND BOTTOM SASH FRONT ROOM 2 STY APT 2LF BOTH WINDOWS. , SECTION '' ''
Class BClosed—Jan 11, 2006FILE PLANS & OBTAIN CERTIFICATE OF OCCUPANCY OR RESTORE · HOTEL AND CERTAIN OTHER CLASS A & CLASS B DWELLINGS§ 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION PARTITION ERECTED AT 2 STY NORTHWEST TO DIVIDED APT AT BATHROOM HALL.
Class BClosed2LFJan 11, 2006REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS MISSING 2 STY APT 2LF MR JEFF HAREN. LOCATED AT APT 2LF
Class BClosed4LJan 11, 2006REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 4 STY WEST APT 4L MR ROLANDO. LOCATED AT APT 4L, 4th STORY, SECTION '' ''
Class BClosedRENT IMPAIRING—Jan 11, 2006REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CHAIRS AND BOXES AT 2 STY PUBLIC HALL.
Class CClosed—Jan 11, 2006ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOOSE AND COLLAPSING BRICKWORK OF DISUSED NORTH AND SOUTH CHIMNEYS AT WEST PARAPET ROOF ER1.
Class BClosed—Jan 11, 2006SCUTTLE LADDER NOT STATIONARY · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF 4 STY PUB HALL SCUTTLE.
Class BClosed2LFJan 11, 2006REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH FIRE ESCAPE WINDOW FRONT ROOM 2 STY APT 2LF. LOCATED AT APT 2LF
Class CClosed—Jan 11, 2006SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SECTION OF WOOD CORNICE LOOSE AND HANGING PULLING AWAY FROM PARAPET WALL AT EAST AT SOUTH CORNER ER1.
Class CClosed1FDec 7, 2005ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Class CClosed—Aug 8, 2005PROVIDE · MAINTENANCESECTION 27-2005 ADM CODE PROVIDE TEMPORARY SECURINGOF ALL ACCESSIBLE OPENINGS ON VACANT BUILDING
Class BClosed1FLJan 24, 2005NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 24, 2005REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 24, 2005REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 24, 2005REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC WALL TILE IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 24, 2005ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 24, 2005REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR .. EAST WALL, SOUTH WALL, NORTH WALL, CEILING IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 13, 2005RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC TILE AT NORTH WALL IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 13, 2005REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION , LEAKING WASTELINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 13, 2005REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CEILING TILE IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed1FLJan 10, 2005REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE NORTH 1 RADIATOR, ESCAPING STEAM AT SHUT OFF VALVE IN THE 1st ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 10, 2005REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 10, 2005REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , CEILING IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 10, 2005ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED WIRES AT CEILING FIXTURE IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 10, 2005SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE TILE AT WEST WALL, AND SOUTH WINDOW HEADER IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed1FLJan 10, 2005REPAIR · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE NORTH 1 RADIATOR,ESCAPING STEAM AT SHUT OFF VALVE IN THE 3rd ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 10, 2005REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CEILING TILE IN THE 3rd ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 10, 2005RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR JAMB AT DOOR HINGE IN THE 3rd ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1FLJan 10, 2005NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed—Jan 5, 2005NO LIGHT AT ENTRANCE TO BUILDING · ARTIFICIAL LIGHTING§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS NO LIGHTS ON .
Class COpen3RNov 17, 2004LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINTSECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FROM SOUTH AT WEST WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen3RNov 17, 2004LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINTSECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL IN THE 1st KITCHEN FROM NORTH AT WEST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen3RNov 17, 2004LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINTSECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen3RNov 17, 2004LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINTSECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 1st BATHROOM FROM NORTH AT EAST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen3RNov 17, 2004LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINTSECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL, 1st WINDOW FRAME FROM NORTH AT EAST WALL, 1st WINDOW SASH FROM NORTH AT EAST WALL IN THE 1st BATHROOM FROM EAST AT NORTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen3RNov 17, 2004LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINTSECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jan 25, 2006Apt 2R
§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE SHOWER BODY VALVE HANDLE IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY
§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE SHOWER BODY VALVE HANDLE IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY
Class BClosed
Jan 25, 2006Apt 2R
REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2018.4 ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY
Class BClosed
Jan 25, 2006Apt 2R
REMOVE VERMIN · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2018.4 ABATE THE NUISANCE CONSISTING OF VERMIN BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY
Class BClosed
Jan 11, 2006Apt 2R
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS MISSING AT 2 STY APT 2R TENANT MR SANDOLAN. , SECTION '' ''
Class BClosed
Jan 11, 2006
PROVIDE LIGHT - Not Less that 60 Watt incadescent · ARTIFICIAL LIGHTING
§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION 2 STY PUBLIC HALL.
Class BClosed
Jan 11, 2006Apt 2LF
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING BATHROOM 2 STY APT 2LF. LOCATED AT APT 2LF
Class BClosed
Jan 11, 2006
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL AT BATHROOM 2 STY NORTHWEST APT.
Class BClosed
Jan 11, 2006
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK CLIPS AT TOP AND BOTTOM WINDOW SASHES AT NORTH ROOM 2 STY N ORTHWEST APT.
Class CClosed
Jan 11, 2006
POST BOILER ROOM ACCESS NOTICE · HEAT AND HOT WATER
§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT OR NEAR MAILBOXES 1 STY PUBLIC HALL AND BOILER ROOM DOOR.
Class CClosed
Jan 11, 2006
PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED CELLAR DOOR AT 1 STY PUBLIC HALL.
Class BClosed
Jan 11, 2006Apt 2R
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 2 STY EAST APT 2R MRS NICHOLAS. LOCATED AT APT 2R
Class CClosed
Jan 11, 2006Apt 2L
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF NO ELECTRIC SERVICE PROVIDED AT LIGHT FIXTURE AT 2 STY NORTHWEST APT 2L AS PER 27-2057 HMC ER1. LOCATED AT APT 2L
Class BClosed
Jan 11, 2006Apt 2LF
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE CEILING FRONT ROOM 2 STY APT 2LF. LOCATED AT APT 2LF
Class CClosed
Jan 11, 2006
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE LOOSE LEANING AND COLLAPSING BRICK WORK AT EAST PARAPET AT SOUTH CORNER BEHIND ORNAMENTAL ROOF CORNICE ER1.
Class BClosed
Jan 11, 2006Apt 2LF
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE TOP AND BOTTOM SASH FRONT ROOM 2 STY APT 2LF BOTH WINDOWS. , SECTION '' ''
Class BClosed
Jan 11, 2006
FILE PLANS & OBTAIN CERTIFICATE OF OCCUPANCY OR RESTORE · HOTEL AND CERTAIN OTHER CLASS A & CLASS B DWELLINGS
§ 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION PARTITION ERECTED AT 2 STY NORTHWEST TO DIVIDED APT AT BATHROOM HALL.
Class BClosed
Jan 11, 2006Apt 2LF
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS MISSING 2 STY APT 2LF MR JEFF HAREN. LOCATED AT APT 2LF
Class BClosed
Jan 11, 2006Apt 4L
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 4 STY WEST APT 4L MR ROLANDO. LOCATED AT APT 4L, 4th STORY, SECTION '' ''
Class BClosedRENT IMPAIRING
Jan 11, 2006
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CHAIRS AND BOXES AT 2 STY PUBLIC HALL.
Class CClosed
Jan 11, 2006
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOOSE AND COLLAPSING BRICKWORK OF DISUSED NORTH AND SOUTH CHIMNEYS AT WEST PARAPET ROOF ER1.
Class BClosed
Jan 11, 2006
SCUTTLE LADDER NOT STATIONARY · EGRESS
§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF 4 STY PUB HALL SCUTTLE.
Class BClosed
Jan 11, 2006Apt 2LF
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH FIRE ESCAPE WINDOW FRONT ROOM 2 STY APT 2LF. LOCATED AT APT 2LF
Class CClosed
Jan 11, 2006
SECURE LOOSE MATTER · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SECTION OF WOOD CORNICE LOOSE AND HANGING PULLING AWAY FROM PARAPET WALL AT EAST AT SOUTH CORNER ER1.
Class CClosed
Dec 7, 2005Apt 1F
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
Class CClosed
Aug 8, 2005
PROVIDE · MAINTENANCE
SECTION 27-2005 ADM CODE PROVIDE TEMPORARY SECURINGOF ALL ACCESSIBLE OPENINGS ON VACANT BUILDING
Class BClosed
Jan 24, 2005Apt 1FL
NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 24, 2005Apt 1FL
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 24, 2005Apt 1FL
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 24, 2005Apt 1FL
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC WALL TILE IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 24, 2005Apt 1FL
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 24, 2005Apt 1FL
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR .. EAST WALL, SOUTH WALL, NORTH WALL, CEILING IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 13, 2005Apt 1FL
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC TILE AT NORTH WALL IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 13, 2005Apt 1FL
REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION , LEAKING WASTELINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 13, 2005Apt 1FL
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CEILING TILE IN THE BATHROOM LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed
Jan 10, 2005Apt 1FL
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE NORTH 1 RADIATOR, ESCAPING STEAM AT SHUT OFF VALVE IN THE 1st ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 10, 2005Apt 1FL
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 10, 2005Apt 1FL
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , CEILING IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 10, 2005Apt 1FL
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED WIRES AT CEILING FIXTURE IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 10, 2005Apt 1FL
SECURE LOOSE MATTER · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE TILE AT WEST WALL, AND SOUTH WINDOW HEADER IN THE KITCHEN LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed
Jan 10, 2005Apt 1FL
REPAIR · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE NORTH 1 RADIATOR,ESCAPING STEAM AT SHUT OFF VALVE IN THE 3rd ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 10, 2005Apt 1FL
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CEILING TILE IN THE 3rd ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 10, 2005Apt 1FL
RETIRED - REPLACE WITH NEW THE BROKEN AND DEFECTIVE · RETIRED
§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR JAMB AT DOOR HINGE IN THE 3rd ROOM FROM EAST LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 10, 2005Apt 1FL
NO CO DETECTOR OR DETECTOR NOT OPERATIONAL · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Jan 5, 2005
NO LIGHT AT ENTRANCE TO BUILDING · ARTIFICIAL LIGHTING
§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS NO LIGHTS ON .
Class COpen
Nov 17, 2004Apt 3R
LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FROM SOUTH AT WEST WALL, 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen
Nov 17, 2004Apt 3R
LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM NORTH AT EAST WALL IN THE 1st KITCHEN FROM NORTH AT WEST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen
Nov 17, 2004Apt 3R
LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen
Nov 17, 2004Apt 3R
LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 1st BATHROOM FROM NORTH AT EAST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen
Nov 17, 2004Apt 3R
LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL, 1st WINDOW FRAME FROM NORTH AT EAST WALL, 1st WINDOW SASH FROM NORTH AT EAST WALL IN THE 1st BATHROOM FROM EAST AT NORTH LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen
Nov 17, 2004Apt 3R
LEAD-BASED PAINT HAZARD- PRESUMED PAINT · LEAD-BASED PAINT
SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st DOOR FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
Page 72 of 92