stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

552 FLATBUSH AVENUE

Brooklyn · ZIP 11225 · BIN 3114595 · Prospect Lefferts Gardens-Wingate · Last violation Jul 23, 2026 · Last complaint Jul 23, 2026

NeighborhoodProspect Lefferts Gardens-Wingate
More violations than 96% of nearby buildings
More violations than 96% of buildings and more complaints than 98% of buildings in Prospect Lefferts Gardens-Wingate. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 407 violations · 482 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
45 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous45Class Bhazardous62
Housing Preservation & Development Violations
Total violations since 2004
1,117
49 per year avg.↑ Up 36% in the last 2 years (407 vs 300 prior 2 yrs)
Open violations
121
Class C (immed. haz.)ⓘ45
Class B (hazardous)ⓘ62
Rent-impairingⓘ16
Housing Preservation & Development Complaints
Total complaints since 2003
2,499
104 per year avg.→ Stable in the last 2 years
Complaint Resolution
No access14%Violation issued21%No violation29%Phone resolved35%Other0%(2,499)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ275 violations
Egressⓘ121 violations
Extermination & Rodent Eradicationⓘ89 violations
Paintingⓘ48 violations
Water Supplyⓘ46 violations
Carbon Monoxide Detecting Devicesⓘ34 violations
Smoke Detecting Devicesⓘ32 violations
Heat And Hot Waterⓘ28 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ406 complaints
Water & plumbingⓘ181 complaints
Mold & pestsⓘ155 complaints
Bldg maintenanceⓘ148 complaints
Electricalⓘ22 complaints
Safety & fireⓘ11 complaints
Elevatorⓘ6 complaints
Appliancesⓘ6 complaints
Adminⓘ2 complaints
Hide violations ↑See complaints →

Violation log

121 violations · Open

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Open violation ages
▪ < 30 days20% (24)
▪ 30–90 days26% (32)
▪ 3–12 months22% (27)
▪ 1–3 years22% (27)
▪ 3+ years9% (11)
Prior 4 yr.
Immed. Emergency12%3%
Emergency63%57%
Non-Emergency25%40%
(230)
(805)
Issued
Description
Class BOpen6JJul 23, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 6J, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen6JJul 23, 2026REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH, 2ND WINDOW AT EAST FROM NORTH IN THE 1st ROOM FROM EAST LOCATED AT APT 6J, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpenRENT IMPAIRING—Jul 23, 2026REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS/FURNITURE AT PUBLIC HALL, 2nd STORY
Class COpen6JJul 23, 2026ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6J, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen—Jul 23, 2026REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE ON LOWER SASH AT 2ND WINDOW FROM SOUTH AT WEST WALL INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 4th STORY
Class COpen1HJul 17, 2026ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class AOpen1HJul 17, 2026TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAT 10 SQ.FT AT CEILING IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen1HJul 17, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class AOpen5AJul 17, 2026PAINT · PAINTING§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen1HJul 17, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen1HJul 17, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen1HJul 17, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen5LJul 15, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5L, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen5LJul 15, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5L, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpenRENT IMPAIRING—Jul 15, 2026REMOVE ENCUMBRANCES · EGRESS§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 2nd STORY
Class BOpenRENT IMPAIRING5LJul 15, 2026INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE ENTIRE APARTMENT LOCATED AT APT 5L, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen2KJul 10, 2026REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class COpen4AJul 10, 2026ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class COpen2KJul 10, 2026ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BOpen2KJul 10, 2026REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class COpen2KJul 10, 2026ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class COpen4AJul 10, 2026ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen6DJul 7, 2026REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTERBALANCE AT LOWER WINDOW SASH IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
Class BOpen—Jul 7, 2026ADJUST DOOR TO PREVENT GAP - FIRE CODE/EGRESS · EGRESS28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AND SILL AT FIRE DOORS AT PUBLIC HALL, 2nd STORY
Class BOpen4BJul 6, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN REGLAZE AT BATHTUB IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen4BJul 6, 2026ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AOpen4BJul 6, 2026FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION PARTITION WALL ERECTED FLOOR TO CEILING CREATING ADDITIONAL ROOM IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpenRENT IMPAIRING6CJul 1, 2026INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class BOpenRENT IMPAIRING6CJul 1, 2026INADEQUATE COLD WATER · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class BOpenRENT IMPAIRING6CJul 1, 2026INADEQUATE COLD WATER · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class COpenRENT IMPAIRING6CJul 1, 2026INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class AOpen6DJun 30, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS AT INTERRIOR OF CLOSET 2ND FROM WEST AT NORTH IN THE PRIVATE HALLWAY LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
Class COpenRENT IMPAIRING5EJun 29, 2026INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpenRENT IMPAIRING5EJun 29, 2026INADEQUATE COLD WATER · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen5EJun 29, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen5EJun 29, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpenRENT IMPAIRING5EJun 29, 2026INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen5EJun 29, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BASE CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AOpen5EJun 29, 2026TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT BASE CABINET UNDER SINK AT SOUTH IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen5EJun 29, 2026REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpenRENT IMPAIRING5EJun 29, 2026INADEQUATE COLD WATER · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen5EJun 29, 2026REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT DOOR AT EAST IN THE ENTRANCE LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class COpen5EJun 29, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class COpen5EJun 29, 2026MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH IN THE ENTRANCE LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class COpen—Jun 12, 2026ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PROPANE TANK AT COMPACTOR CLOSET, 1st STORY
Class BOpen2BJun 2, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MARBLE SADDLE AT DOOR IN THE ENTRANCE LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Class BOpen2BJun 2, 2026REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE AT BATHTUB IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Class COpen2BJun 2, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Class BOpen2BJun 2, 2026REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE FOYER LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Class COpen2BJun 2, 2026ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Class BOpen
Jul 23, 2026Apt 6J
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 6J, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 23, 2026Apt 6J
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH, 2ND WINDOW AT EAST FROM NORTH IN THE 1st ROOM FROM EAST LOCATED AT APT 6J, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpenRENT IMPAIRING
Jul 23, 2026
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS/FURNITURE AT PUBLIC HALL, 2nd STORY
Class COpen
Jul 23, 2026Apt 6J
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6J, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 23, 2026
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE ON LOWER SASH AT 2ND WINDOW FROM SOUTH AT WEST WALL INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 4th STORY
Class COpen
Jul 17, 2026Apt 1H
ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class AOpen
Jul 17, 2026Apt 1H
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAT 10 SQ.FT AT CEILING IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen
Jul 17, 2026Apt 1H
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class AOpen
Jul 17, 2026Apt 5A
PAINT · PAINTING
§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 17, 2026Apt 1H
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen
Jul 17, 2026Apt 1H
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen
Jul 17, 2026Apt 1H
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1H, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen
Jul 15, 2026Apt 5L
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5L, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 15, 2026Apt 5L
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5L, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpenRENT IMPAIRING
Jul 15, 2026
REMOVE ENCUMBRANCES · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 2nd STORY
Class BOpenRENT IMPAIRING
Jul 15, 2026Apt 5L
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE ENTIRE APARTMENT LOCATED AT APT 5L, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 10, 2026Apt 2K
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class COpen
Jul 10, 2026Apt 4A
ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class COpen
Jul 10, 2026Apt 2K
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 10, 2026Apt 2K
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class COpen
Jul 10, 2026Apt 2K
ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 3rd APARTMENT FROM NORTH AT EAST
Class COpen
Jul 10, 2026Apt 4A
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jul 7, 2026Apt 6D
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTERBALANCE AT LOWER WINDOW SASH IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
Class BOpen
Jul 7, 2026
ADJUST DOOR TO PREVENT GAP - FIRE CODE/EGRESS · EGRESS
28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AND SILL AT FIRE DOORS AT PUBLIC HALL, 2nd STORY
Class BOpen
Jul 6, 2026Apt 4B
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN REGLAZE AT BATHTUB IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen
Jul 6, 2026Apt 4B
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AOpen
Jul 6, 2026Apt 4B
FILE PLANS OR RESTORE · ALTERATIONS
§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION PARTITION WALL ERECTED FLOOR TO CEILING CREATING ADDITIONAL ROOM IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpenRENT IMPAIRING
Jul 1, 2026Apt 6C
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class BOpenRENT IMPAIRING
Jul 1, 2026Apt 6C
INADEQUATE COLD WATER · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class BOpenRENT IMPAIRING
Jul 1, 2026Apt 6C
INADEQUATE COLD WATER · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class COpenRENT IMPAIRING
Jul 1, 2026Apt 6C
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class AOpen
Jun 30, 2026Apt 6D
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS AT INTERRIOR OF CLOSET 2ND FROM WEST AT NORTH IN THE PRIVATE HALLWAY LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM EAST AT SOUTH
Class COpenRENT IMPAIRING
Jun 29, 2026Apt 5E
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpenRENT IMPAIRING
Jun 29, 2026Apt 5E
INADEQUATE COLD WATER · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Jun 29, 2026Apt 5E
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Jun 29, 2026Apt 5E
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpenRENT IMPAIRING
Jun 29, 2026Apt 5E
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Jun 29, 2026Apt 5E
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BASE CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AOpen
Jun 29, 2026Apt 5E
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT BASE CABINET UNDER SINK AT SOUTH IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Jun 29, 2026Apt 5E
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING, EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpenRENT IMPAIRING
Jun 29, 2026Apt 5E
INADEQUATE COLD WATER · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BOpen
Jun 29, 2026Apt 5E
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT DOOR AT EAST IN THE ENTRANCE LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class COpen
Jun 29, 2026Apt 5E
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class COpen
Jun 29, 2026Apt 5E
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH IN THE ENTRANCE LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class COpen
Jun 12, 2026
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PROPANE TANK AT COMPACTOR CLOSET, 1st STORY
Class BOpen
Jun 2, 2026Apt 2B
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MARBLE SADDLE AT DOOR IN THE ENTRANCE LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Class BOpen
Jun 2, 2026Apt 2B
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE AT BATHTUB IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Class COpen
Jun 2, 2026Apt 2B
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Class BOpen
Jun 2, 2026Apt 2B
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE FOYER LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Class COpen
Jun 2, 2026Apt 2B
ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH
Page 1 of 3