stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

916 FAILE STREET

Bronx · ZIP 10474 · BIN 2006367 · Hunts Point · Last violation Jun 22, 2026 · Last complaint Jul 23, 2026

NeighborhoodHunts Point
More violations than 93% of nearby buildings
More violations than 93% of buildings and more complaints than 90% of buildings in Hunts Point. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
More activity recently than in past years
Last 2 yrs: 683 violations · 435 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
61 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous61Class Bhazardous255
Housing Preservation & Development Violations
Total violations since 1997
1,024
34 per year avg.↑ Up 368% in the last 2 years (683 vs 146 prior 2 yrs)
Open violations
356
Class C (immed. haz.)ⓘ61
Class B (hazardous)ⓘ255
Rent-impairingⓘ16
Housing Preservation & Development Complaints
Total complaints since 2003
776
32 per year avg.↑ Up 936% in the last 2 years (435 vs 42 prior 2 yrs)
Complaint Resolution
No access18%Violation issued36%No violation32%Phone resolved14%Other0%(776)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ442 violations
Paintingⓘ75 violations
Egressⓘ59 violations
Water Supplyⓘ49 violations
Extermination & Rodent Eradicationⓘ41 violations
Carbon Monoxide Detecting Devicesⓘ33 violations
Smoke Detecting Devicesⓘ33 violations
Lead-Based Paintⓘ25 violations
Top complaint groupsⓘ
5 yrsAll time
Bldg maintenanceⓘ141 complaints
Water & plumbingⓘ110 complaints
Heat / hot waterⓘ49 complaints
Appliancesⓘ40 complaints
Mold & pestsⓘ32 complaints
Electricalⓘ25 complaints
Safety & fireⓘ11 complaints
Hide violations ↑See complaints →

Violation log

1,024 violations

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Open violation ages
▪ 30–90 days6% (21)
▪ 3–12 months12% (42)
▪ 1–3 years81% (289)
▪ 3+ years1% (3)
Prior 4 yr.
Immed. Emergency3%2%
Emergency42%40%
Non-Emergency56%58%
(77)
(419)
Issued
Description
Class BClosed2BMay 1, 2025REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT DRAIN PIPE UNDER SINK IN THE KITCHEN LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''South''
Class BClosed2BApr 28, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''South''
Class BOpen2BApr 28, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL INSIDE CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''South''
Class BOpen1EApr 17, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1EApr 17, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed2AApr 17, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2A, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916'', AT SOUTH
Class BOpen2BApr 17, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS INSIDE THE 2ND CLOSET FROM EAST AT NORTH WALL IN THE FOYER LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''916'', AT SOUTH
Class COpen2BApr 17, 2025ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING MAXIMUM TEMPERATURE OF 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''916'', AT SOUTH
Class CClosed1EApr 17, 2025MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen1EApr 17, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed1EApr 17, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class COpen4AApr 17, 2025TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESSS THAN 30 SQ. FT.AT THE CEILING AND SOUTH WALL CEILING IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH ORIGINAL VIOLATION 17153428 ISSUED 30-JUL-24 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27-2017.3a(5)(a) or (b).
Class BOpen1EApr 17, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT WINDOW IN THE KITCHEN LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class COpen5EApr 8, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT LOWER SASH WINDOW IN THE KITCHEN LOCATED AT APT 5E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''916'', AT SOUTH
Class BClosed4AApr 8, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MARBLE SADDLE IN THE ENTRANCE IN THE BATHROOM LOCATED AT APT 4A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''918'', AT NORTH
Class COpen5EApr 8, 2025ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''916'', AT SOUTH
Class BOpen5EApr 8, 2025REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 5E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''916'', AT SOUTH
Class CClosed4AApr 8, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 4A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''918'', AT NORTH
Class CClosedRENT IMPAIRING—Apr 8, 2025REMOVE ILLEGAL FASTENING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CHAIN WITH PADLOCK INSTALLED AT METAL GATE LEADING TO BULKHEAD AT PUBLIC HALL, 6th STORY, SECTION ''918'', AT NORTH
Class CClosed5AApr 7, 2025MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916'', AT SOUTH
Class BClosed—Apr 7, 2025PROVIDE LIGHT - Not Less that 60 Watt incadescent · ARTIFICIAL LIGHTING§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 6th STORY, SECTION ''916'', AT SOUTH
Class BOpen4AMar 13, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES. IN THE BATHROOM LOCATED AT APT 4A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
Class BClosed—Mar 13, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSBELY AT ENTRANCE FROM STREET TO VESTABULE 1ST STORY , 1st STORY
Class BClosed3CMar 13, 2025REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
Class BClosed3CMar 13, 2025REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
Class CClosed—Mar 13, 2025MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES , 6th STORY, SECTION AT SOUTH
Class BOpen—Feb 28, 2025NO LIGHT AT ENTRANCE TO BUILDING · ARTIFICIAL LIGHTING§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING AT FRONT COURT YARD COURT, 1st STORY
Class CClosed—Feb 28, 2025MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE , 1st STORY
Class CClosed5AFeb 28, 2025ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class CClosed5AFeb 28, 2025MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed5AFeb 28, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed5AFeb 28, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW STOOL AT WEST WALL. (FALLING OFF) IN THE 3rd ROOM FROM EAST LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed5AFeb 28, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW STOOL AT NORTH WALL. (FALLING OFF) IN THE 3rd ROOM FROM EAST LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosedRENT IMPAIRING5AFeb 28, 2025LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BOpen5AFeb 28, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed—Feb 28, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR , 1st STORY
Class BClosedRENT IMPAIRING5AFeb 28, 2025INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATH TUB IN THE BATHROOM LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed5AFeb 28, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class CClosed2AFeb 25, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER SPRING BALANCE AT LOWER WINDOW SASH IN THE 3rd ROOM FROM EAST LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class CClosed5AFeb 24, 2025ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATIONHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class CClosed—Feb 24, 2025PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKRD AT BOILER ROOM
Class CClosed5AFeb 24, 2025MAKE DOORS SELF-CLOSING · EGRESS§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class CClosedRENT IMPAIRING5AFeb 24, 2025INADEQUATE HEAT · HEAT AND HOT WATER§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY
Class COpen3CFeb 11, 2025ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF BROKEN GLASS AT 2ND WINDOW FROM NORTH AT EAST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BOpen3CFeb 11, 2025SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCUTCHION PLATE AT RISER [TOP] IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BClosed—Feb 11, 2025REMOVE ENCUMBRANCE · EGRESS§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ITEMS [(4) WATER JUGS] AT 2ND STORY BALCONY AT 2ND FIRE ESCAPE FROM EAST AT NORTH EXTERIOR WALL AT FIRE ESCAPE
Class CClosed—Feb 11, 2025ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FREESTANDING RADIATOR AT SOUTH WALL AT 2ND STORY SOUTH SECTION AT PUBLIC HALL
Class BOpen—Feb 11, 2025PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE GLASS IN PLACE OF PLEXIGLASS INSTALLED AT 1ST, AND 2ND WINDOW FROM SOUTH AT WEST WALL AT 1ST STORY AT PUBLIC HALL
Class BOpen—Feb 11, 2025ABATE THE NUISANCE · MAINTENANCE§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXIGLASS INSTALLED ON UPPER AND LOWER SASH WINDOW AT NORTH WALL AT 1ST STORY INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, SECTION ''SOUTH''
Class BOpen—Feb 11, 2025PROVIDE · MAINTENANCE§ 27-2005 ADM CODE PROVIDE GLASS IN PLACE OF PLEXIGLASS INSTALLED ON UPPER AND LOWER SASH WINDOW AT NORTH WALL AT 1ST STORY INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, SECTION ''SOUTH''
Class BClosed
May 1, 2025Apt 2B
REPAIR BROKEN, LOOSE CONNECTION · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT DRAIN PIPE UNDER SINK IN THE KITCHEN LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''South''
Class BClosed
Apr 28, 2025Apt 2B
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''South''
Class BOpen
Apr 28, 2025Apt 2B
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL INSIDE CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''South''
Class BOpen
Apr 17, 2025Apt 1E
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Apr 17, 2025Apt 1E
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class CClosed
Apr 17, 2025Apt 2A
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2A, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916'', AT SOUTH
Class BOpen
Apr 17, 2025Apt 2B
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS INSIDE THE 2ND CLOSET FROM EAST AT NORTH WALL IN THE FOYER LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''916'', AT SOUTH
Class COpen
Apr 17, 2025Apt 2B
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING MAXIMUM TEMPERATURE OF 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''916'', AT SOUTH
Class CClosed
Apr 17, 2025Apt 1E
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Apr 17, 2025Apt 1E
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class BClosed
Apr 17, 2025Apt 1E
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class COpen
Apr 17, 2025Apt 4A
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESSS THAN 30 SQ. FT.AT THE CEILING AND SOUTH WALL CEILING IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH ORIGINAL VIOLATION 17153428 ISSUED 30-JUL-24 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27-2017.3a(5)(a) or (b).
Class BOpen
Apr 17, 2025Apt 1E
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT WINDOW IN THE KITCHEN LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
Class COpen
Apr 8, 2025Apt 5E
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT LOWER SASH WINDOW IN THE KITCHEN LOCATED AT APT 5E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''916'', AT SOUTH
Class BClosed
Apr 8, 2025Apt 4A
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MARBLE SADDLE IN THE ENTRANCE IN THE BATHROOM LOCATED AT APT 4A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''918'', AT NORTH
Class COpen
Apr 8, 2025Apt 5E
ABATE THE NUISANCE OF MICE · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''916'', AT SOUTH
Class BOpen
Apr 8, 2025Apt 5E
REMOVE BARS OR GATES FROM FIRE ESCAPE WINDOW · EGRESS
§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 5E, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''916'', AT SOUTH
Class CClosed
Apr 8, 2025Apt 4A
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 4A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''918'', AT NORTH
Class CClosedRENT IMPAIRING
Apr 8, 2025
REMOVE ILLEGAL FASTENING · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CHAIN WITH PADLOCK INSTALLED AT METAL GATE LEADING TO BULKHEAD AT PUBLIC HALL, 6th STORY, SECTION ''918'', AT NORTH
Class CClosed
Apr 7, 2025Apt 5A
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916'', AT SOUTH
Class BClosed
Apr 7, 2025
PROVIDE LIGHT - Not Less that 60 Watt incadescent · ARTIFICIAL LIGHTING
§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 6th STORY, SECTION ''916'', AT SOUTH
Class BOpen
Mar 13, 2025Apt 4A
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES. IN THE BATHROOM LOCATED AT APT 4A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH
Class BClosed
Mar 13, 2025
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSBELY AT ENTRANCE FROM STREET TO VESTABULE 1ST STORY , 1st STORY
Class BClosed
Mar 13, 2025Apt 3C
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
Class BClosed
Mar 13, 2025Apt 3C
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTH
Class CClosed
Mar 13, 2025
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES , 6th STORY, SECTION AT SOUTH
Class BOpen
Feb 28, 2025
NO LIGHT AT ENTRANCE TO BUILDING · ARTIFICIAL LIGHTING
§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING AT FRONT COURT YARD COURT, 1st STORY
Class CClosed
Feb 28, 2025
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT BUILDING ENTRANCE , 1st STORY
Class CClosed
Feb 28, 2025Apt 5A
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class CClosed
Feb 28, 2025Apt 5A
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed
Feb 28, 2025Apt 5A
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed
Feb 28, 2025Apt 5A
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW STOOL AT WEST WALL. (FALLING OFF) IN THE 3rd ROOM FROM EAST LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed
Feb 28, 2025Apt 5A
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW STOOL AT NORTH WALL. (FALLING OFF) IN THE 3rd ROOM FROM EAST LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosedRENT IMPAIRING
Feb 28, 2025Apt 5A
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BOpen
Feb 28, 2025Apt 5A
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed
Feb 28, 2025
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT BUILDING ENTRANCE DOOR , 1st STORY
Class BClosedRENT IMPAIRING
Feb 28, 2025Apt 5A
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATH TUB IN THE BATHROOM LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class BClosed
Feb 28, 2025Apt 5A
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 5A, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''916''
Class CClosed
Feb 25, 2025Apt 2A
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER SPRING BALANCE AT LOWER WINDOW SASH IN THE 3rd ROOM FROM EAST LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
Class CClosed
Feb 24, 2025Apt 5A
ABATE THE NUISANCE OF ROACHES · EXTERMINATION & RODENT ERADICATION
HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class CClosed
Feb 24, 2025
PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKRD AT BOILER ROOM
Class CClosed
Feb 24, 2025Apt 5A
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class CClosedRENT IMPAIRING
Feb 24, 2025Apt 5A
INADEQUATE HEAT · HEAT AND HOT WATER
§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY
Class COpen
Feb 11, 2025Apt 3C
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF BROKEN GLASS AT 2ND WINDOW FROM NORTH AT EAST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BOpen
Feb 11, 2025Apt 3C
SECURE LOOSE MATTER · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCUTCHION PLATE AT RISER [TOP] IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''
Class BClosed
Feb 11, 2025
REMOVE ENCUMBRANCE · EGRESS
§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ITEMS [(4) WATER JUGS] AT 2ND STORY BALCONY AT 2ND FIRE ESCAPE FROM EAST AT NORTH EXTERIOR WALL AT FIRE ESCAPE
Class CClosed
Feb 11, 2025
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FREESTANDING RADIATOR AT SOUTH WALL AT 2ND STORY SOUTH SECTION AT PUBLIC HALL
Class BOpen
Feb 11, 2025
PROVIDE · MAINTENANCE
§ 27-2005 ADM CODE PROVIDE GLASS IN PLACE OF PLEXIGLASS INSTALLED AT 1ST, AND 2ND WINDOW FROM SOUTH AT WEST WALL AT 1ST STORY AT PUBLIC HALL
Class BOpen
Feb 11, 2025
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXIGLASS INSTALLED ON UPPER AND LOWER SASH WINDOW AT NORTH WALL AT 1ST STORY INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, SECTION ''SOUTH''
Class BOpen
Feb 11, 2025
PROVIDE · MAINTENANCE
§ 27-2005 ADM CODE PROVIDE GLASS IN PLACE OF PLEXIGLASS INSTALLED ON UPPER AND LOWER SASH WINDOW AT NORTH WALL AT 1ST STORY INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, SECTION ''SOUTH''
Page 4 of 21