stoop
MAP
LeaderboardAbout
Building SafetyHousing Conditions

1423 AMSTERDAM AVENUE

Manhattan · ZIP 10027 · BIN 1075479 · Manhattanville-West Harlem · Last violation Jul 23, 2026 · Last complaint Jul 31, 2026

NeighborhoodManhattanville-West Harlem
Above-average violations for the neighborhood
More violations than 74% of buildings and more complaints than 88% of buildings in Manhattanville-West Harlem. Size-normalized against residential buildings in the neighborhood for issues in the last 10 years.
ViolationsComplaints
Activity TrendsLast 5 years
A steady level of activity over time
Last 2 yrs: 309 violations · 663 complaints
'21'26ViolationsComplaints
▼ View all activity over time
Severityⓘopen violations
13 immediately hazardous (Class C) violations still open
Class C violations include lead paint, mold, pest infestations, heat/hot water failure, and structural hazards — the most serious category.
Class Cimmediately hazardous13Class Bhazardous76
Housing Preservation & Development Violations
Total violations since 1990
1,246
34 per year avg.↓ Down 25% in the last 2 years (309 vs 414 prior 2 yrs)
Open violations
111
Class C (immed. haz.)ⓘ13
Class B (hazardous)ⓘ76
Rent-impairingⓘ3
Housing Preservation & Development Complaints
Total complaints since 2003
1,820
76 per year avg.↑ Up 63% in the last 2 years (663 vs 407 prior 2 yrs)
Complaint Resolution
No access14%Violation issued25%No violation38%Phone resolved23%Other0%(1,820)
Urgency breakdown
Last 12 mo.

Top violation categories

5 yrsAll time
Maintenanceⓘ291 violations
Egressⓘ95 violations
Water Supplyⓘ79 violations
Cleaningⓘ66 violations
Extermination & Rodent Eradicationⓘ52 violations
Smoke Detecting Devicesⓘ44 violations
Carbon Monoxide Detecting Devicesⓘ44 violations
Paintingⓘ42 violations
Top complaint groupsⓘ
5 yrsAll time
Heat / hot waterⓘ327 complaints
Water & plumbingⓘ228 complaints
Bldg maintenanceⓘ152 complaints
Mold & pestsⓘ128 complaints
Electricalⓘ66 complaints
Appliancesⓘ56 complaints
Elevatorⓘ33 complaints
Safety & fireⓘ30 complaints
Adminⓘ2 complaints
Outdoor / structuralⓘ1 complaints
Hide violations ↑See complaints →

Violation log

1,246 violations

All classesClass AClass BClass CClass IAllOpenClosed
ClassStatusApt
See something wrong? File a complaint with 311
Open violation ages
▪ < 30 days12% (13)
▪ 30–90 days14% (16)
▪ 3–12 months48% (53)
▪ 1–3 years23% (26)
▪ 3+ years3% (3)
Prior 4 yr.
Immed. Emergency1%1%
Emergency59%56%
Non-Emergency40%43%
(199)
(981)
Issued
Description
Class BClosed5AAug 21, 2025REFIT DOORS ETC. · EGRESS§ 27-2005 HMC: REFIT THE DOOR IN THE ENTRANCE LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed4PAug 21, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL. IN THE 1st ROOM FROM EAST LOCATED AT APT 4P, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed4PAug 21, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL. IN THE BATHROOM LOCATED AT APT 4P, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed4NAug 14, 2025SECURE LOOSE MATTER · MAINTENANCE§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SLIDING DOOR AT CLOSET AT WEST WALL IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class BClosed4NAug 11, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC-TILES AT BATHTUB IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class AClosed4NAug 11, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND THE WASH/BASIN IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class AClosed4NAug 11, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND THE BATHTUB IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class BClosed4NAug 11, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class BClosed4NAug 11, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class BClosed8MAug 4, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL AIR VENT AT EAST WALL IN THE BATHROOM LOCATED AT APT 8M, 9th STORY, 4th APARTMENT FROM WEST AT NORTH
Class BOpen8MAug 4, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 8M, 9th STORY, 4th APARTMENT FROM WEST AT NORTH
Class BClosedRENT IMPAIRING8RAug 4, 2025LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 8R, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class AClosed6AAug 4, 2025TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 6A, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosedRENT IMPAIRING8OAug 4, 2025LEAKY ROOF · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 8O, 9th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed8CAug 4, 2025REFIT DOORS ETC. · EGRESS§ 27-2005 HMC: REFIT DOOR AT BALCONY IN THE 1st ROOM FROM NORTH LOCATED AT APT 8C, 9th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed6EAug 4, 2025REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen8RAug 4, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL AIR VENT AT NORTH WALL IN THE KITCHEN LOCATED AT APT 8R, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class BClosed8CAug 4, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WALL CABINET AT EAST IN THE KITCHEN LOCATED AT APT 8C, 9th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed6EAug 4, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 6E, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed8OAug 4, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 8O, 9th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen8RAug 4, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 8R, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class AOpen—Aug 4, 2025FILE PLANS OR RESTORE · ALTERATIONS§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING AT PUBLIC HALL, 9th STORY
Class BClosed6EAug 4, 2025REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosedRENT IMPAIRINGLBJul 31, 2025INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRINGLBJul 31, 2025INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed6BJul 29, 2025REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 6B, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed6BJul 29, 2025REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BASE CABINET AT WEST WALL IN THE KITCHEN LOCATED AT APT 6B, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedLBJul 29, 2025TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedLBJul 29, 2025PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE KITCHEN LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRINGLBJul 29, 2025REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed4PJul 29, 2025REPAIR LEAKY FAUCETS · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4P, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING6BJul 29, 2025REPAIR LEAKY PIPES · WATER SUPPLY§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT SINK IN THE KITCHEN LOCATED AT APT 6B, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedLBJul 29, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRINGLBJul 29, 2025REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT WASHBASIN IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRINGLBJul 15, 2025INADEQUATE COLD WATER · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRINGLBJul 15, 2025INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BOpenRENT IMPAIRINGLBJul 11, 2025INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed4PJul 2, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RADIATOR COVER AT EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 4P, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AOpen4PJul 2, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE KITCHEN LOCATED AT APT 4P, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed5CJun 27, 2025REPAIR WITH SIMILAR MATERIAL · MAINTENANCE§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH AT BATHTUB IN THE BATHROOM LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed4PJun 12, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 4P, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AClosed4PJun 12, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 4P, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed—Jun 9, 2025DOOR NOT SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WOOD CHUCK AT DOOR AT NORTH , 1st STORY
Class CClosed—Jun 9, 2025DOOR NOT SELF-CLOSING · EGRESS§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING RUBBER WEDGE AT LAUNDRY ROOM, 1st STORY
Class CClosed5AJun 9, 2025REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen5AJun 9, 2025REPAIR PLASTER · MAINTENANCE§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class AClosed—Jun 9, 2025REPLACE · MAINTENANCE§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY COVER FOR ELECTRICAL OUTLETS AT 3RD,4TH AND 5TH STORY NORTH AND WEST WALL AT PUBLIC HALL
Class BClosed5AJun 9, 2025ADJUST DOOR TO PREVENT GAP - FIRE CODE/EGRESS · EGRESS28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AND SILL AT ..... IN THE ENTRANCE LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed4MMay 12, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER CABINET AT NORTH IN THE KITCHEN LOCATED AT APT 4M, 5th STORY, 4th APARTMENT FROM WEST AT NORTH , SECTION ''NORTH''
Class BClosed4MApr 11, 2025REPAIR · MAINTENANCE§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 4M, 4th STORY, 4th APARTMENT FROM WEST AT NORTH
Class BClosed
Aug 21, 2025Apt 5A
REFIT DOORS ETC. · EGRESS
§ 27-2005 HMC: REFIT THE DOOR IN THE ENTRANCE LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
Aug 21, 2025Apt 4P
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL. IN THE 1st ROOM FROM EAST LOCATED AT APT 4P, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Aug 21, 2025Apt 4P
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL. IN THE BATHROOM LOCATED AT APT 4P, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed
Aug 14, 2025Apt 4N
SECURE LOOSE MATTER · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE SLIDING DOOR AT CLOSET AT WEST WALL IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class BClosed
Aug 11, 2025Apt 4N
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC-TILES AT BATHTUB IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class AClosed
Aug 11, 2025Apt 4N
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND THE WASH/BASIN IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class AClosed
Aug 11, 2025Apt 4N
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND THE BATHTUB IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class BClosed
Aug 11, 2025Apt 4N
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class BClosed
Aug 11, 2025Apt 4N
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 4N, 4th STORY, 5th APARTMENT FROM WEST AT NORTH
Class BClosed
Aug 4, 2025Apt 8M
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL AIR VENT AT EAST WALL IN THE BATHROOM LOCATED AT APT 8M, 9th STORY, 4th APARTMENT FROM WEST AT NORTH
Class BOpen
Aug 4, 2025Apt 8M
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 8M, 9th STORY, 4th APARTMENT FROM WEST AT NORTH
Class BClosedRENT IMPAIRING
Aug 4, 2025Apt 8R
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 8R, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class AClosed
Aug 4, 2025Apt 6A
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 6A, 7th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosedRENT IMPAIRING
Aug 4, 2025Apt 8O
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 8O, 9th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed
Aug 4, 2025Apt 8C
REFIT DOORS ETC. · EGRESS
§ 27-2005 HMC: REFIT DOOR AT BALCONY IN THE 1st ROOM FROM NORTH LOCATED AT APT 8C, 9th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 4, 2025Apt 6E
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BOpen
Aug 4, 2025Apt 8R
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL AIR VENT AT NORTH WALL IN THE KITCHEN LOCATED AT APT 8R, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class BClosed
Aug 4, 2025Apt 8C
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WALL CABINET AT EAST IN THE KITCHEN LOCATED AT APT 8C, 9th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 4, 2025Apt 6E
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 6E, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosed
Aug 4, 2025Apt 8O
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 8O, 9th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Aug 4, 2025Apt 8R
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 8R, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTH
Class AOpen
Aug 4, 2025
FILE PLANS OR RESTORE · ALTERATIONS
§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING AT PUBLIC HALL, 9th STORY
Class BClosed
Aug 4, 2025Apt 6E
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST
Class BClosedRENT IMPAIRING
Jul 31, 2025Apt LB
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Jul 31, 2025Apt LB
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jul 29, 2025Apt 6B
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 6B, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jul 29, 2025Apt 6B
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BASE CABINET AT WEST WALL IN THE KITCHEN LOCATED AT APT 6B, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jul 29, 2025Apt LB
TRACE & REPAIR THE SOURCE & ABATE THE…MOLD · CLEANING
§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jul 29, 2025Apt LB
PROVIDE SUPPLY OF ELECTRICTY TO FIXTURES · ARTIFICIAL LIGHTING
§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE KITCHEN LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Jul 29, 2025Apt LB
REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jul 29, 2025Apt 4P
REPAIR LEAKY FAUCETS · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 4P, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Jul 29, 2025Apt 6B
REPAIR LEAKY PIPES · WATER SUPPLY
§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT SINK IN THE KITCHEN LOCATED AT APT 6B, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jul 29, 2025Apt LB
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Jul 29, 2025Apt LB
REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT WASHBASIN IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Jul 15, 2025Apt LB
INADEQUATE COLD WATER · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Jul 15, 2025Apt LB
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BOpenRENT IMPAIRING
Jul 11, 2025Apt LB
INADEQUATE HOT WATER SUPPLY (VOLUME) · WATER SUPPLY
§ 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT LB, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jul 2, 2025Apt 4P
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RADIATOR COVER AT EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 4P, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AOpen
Jul 2, 2025Apt 4P
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE KITCHEN LOCATED AT APT 4P, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Jun 27, 2025Apt 5C
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH AT BATHTUB IN THE BATHROOM LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST
Class AClosed
Jun 12, 2025Apt 4P
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 4P, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AClosed
Jun 12, 2025Apt 4P
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 4P, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed
Jun 9, 2025
DOOR NOT SELF-CLOSING · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WOOD CHUCK AT DOOR AT NORTH , 1st STORY
Class CClosed
Jun 9, 2025
DOOR NOT SELF-CLOSING · EGRESS
§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING RUBBER WEDGE AT LAUNDRY ROOM, 1st STORY
Class CClosed
Jun 9, 2025Apt 5A
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BOpen
Jun 9, 2025Apt 5A
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class AClosed
Jun 9, 2025
REPLACE · MAINTENANCE
§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SAFETY COVER FOR ELECTRICAL OUTLETS AT 3RD,4TH AND 5TH STORY NORTH AND WEST WALL AT PUBLIC HALL
Class BClosed
Jun 9, 2025Apt 5A
ADJUST DOOR TO PREVENT GAP - FIRE CODE/EGRESS · EGRESS
28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AND SILL AT ..... IN THE ENTRANCE LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST
Class BClosed
May 12, 2025Apt 4M
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER CABINET AT NORTH IN THE KITCHEN LOCATED AT APT 4M, 5th STORY, 4th APARTMENT FROM WEST AT NORTH , SECTION ''NORTH''
Class BClosed
Apr 11, 2025Apt 4M
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER CABINET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 4M, 4th STORY, 4th APARTMENT FROM WEST AT NORTH