Class COpenRENT IMPAIRING
Feb 25, 2026Apt 8G
INADEQUATE HEAT · HEAT AND HOT WATER
§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM NORTH AT EAST
Class COpen
Feb 25, 2026Apt 8G
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER TEMPERATURE EXCEEDING OF MAXIMUM ALLOWABLE AT 130 F AT ALL HOT WATER FIXTURES THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Feb 23, 2026Apt 7H
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 7H, 7th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''3''
Class BOpen
Feb 23, 2026Apt 7H
DISCOLORED WATER · WATER SUPPLY
HMC- §272024 PROVIDE AND MAINTAIN A PURE AND WHOLESOME WATER SUPPLY THAT WAS FOUND DISCOLORED AT WASHBASIN AND SHOWER IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 7H, 7th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''3''
Class BOpen
Feb 23, 2026Apt 7H
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 7H, 7th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''3''
Class BClosedRENT IMPAIRING
Feb 12, 2026Apt 8G
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 8G UPPER LEVEL, 8th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Feb 12, 2026Apt 8G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 2nd ROOM FROM EAST AT CENTER LOCATED AT APT 8G UPPER LEVEL, 8th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosedRENT IMPAIRING
Feb 12, 2026Apt 8G
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 8G UPPER LEVEL, 8th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosed
Feb 12, 2026Apt 8G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT 8G UPPER LEVEL, 8th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Feb 12, 2026Apt 8G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 8G UPPER LEVEL, 8th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosedRENT IMPAIRING
Feb 12, 2026Apt 8G
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM EAST AT CENTER LOCATED AT APT 8G UPPER LEVEL, 8th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BClosedRENT IMPAIRING
Feb 9, 2026Apt 8G
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Feb 9, 2026Apt 8G
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND SOUTH WALL IN THE KITCHEN LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpenRENT IMPAIRING
Feb 9, 2026Apt 8G
INADEQUATE HEAT · HEAT AND HOT WATER
§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Feb 9, 2026Apt 8G
LEAKY ROOF · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND WEST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AOpen
Feb 9, 2026Apt 8G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BClosed
Feb 9, 2026Apt 8G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AOpen
Feb 9, 2026Apt 8G
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER WINDOW SASH AT SOUTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed
Feb 9, 2026
PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM
Class BClosed
Feb 3, 2026Apt 8L
CORRECT FAILURE TO INSTALL TEMPERATURE REPORTING DEVICE · HEAT SENSOR PROGRAM
§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 8L, 8th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''JKLM''
Class CClosed
Feb 3, 2026Apt 8L
INSTALL/REPLACE/REPAIR WINDOW GUARDS (APT) · WINDOW GUARDS
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 8L, 8th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''JKLM''
Class BOpen
Feb 2, 2026Apt 8G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BOpen
Feb 2, 2026Apt 8G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND SOUTH WALL IN THE KITCHEN LOCATED AT APT 8G, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class COpen
Jan 21, 2026
CORRECT FAILURE TO NOTIFY OCCUPANTS · LEAD-BASED PAINT
§ 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS.
Class BClosed
Jan 21, 2026Apt 6G
REPAIR PLASTER · MAINTENANCE
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''GHIJ'', 2nd FROM EAST AT SOUTH
Class BClosed
Jan 21, 2026Apt 6G
REPAIR THE SOURCE AND ABATE THE WATER LEAK · WATER SUPPLY
§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''GHIJ'', 2nd FROM EAST AT SOUTH
Class BClosedRENT IMPAIRING
Jan 21, 2026Apt 6G
REMOVE OBSTRUCTIONS · SEWERS AND DRAINAGE
§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE 1st BATHROOM FROM EAST LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''GHIJ'', 2nd FROM EAST AT SOUTH
Class COpen
Jan 21, 2026
FAILURE TO PROVIDE TO THE DEPT. WITHIN 45 DAYS · LEAD-BASED PAINT
§ 27-2056.4(H) AND 27-2056.17 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES.
Class CClosed
Jan 20, 2026Apt 8A
MAKE DOORS SELF-CLOSING · EGRESS
§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed
Jan 20, 2026Apt 8A
ABATE THE NUISANCE · MAINTENANCE
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM TEMPERATURE OF 130 DEGREES AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosed
Jan 20, 2026
PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR AT BOILER ROOM
Class CClosedRENT IMPAIRING
Jan 20, 2026Apt 8A
INADEQUATE HEAT · HEAT AND HOT WATER
§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class AClosed
Jan 13, 2026Apt 5E
TRANSOM NOT STATIONARY · EGRESS
§ 27-2005 ADM CODE MAKE STATIONARY THE TRANSOM OVER DOOR ... IN THE 1st ROOM FROM EAST AT CENTER LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''DEF''
Class BClosed
Jan 13, 2026Apt 5E
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''DEF''
Class BClosed
Jan 13, 2026
CORRECT FAILURE TO MAINTAIN R RECORDS REGARDING T DEVICES · HEAT SENSOR PROGRAM
§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. DATA REQUESTED FOR THE PERIOD OF NOVEMBER 2025.
Class BClosed
Jan 13, 2026Apt 5E
REPAIR OR REPLACE CO DETECTOR · CARBON MONOXIDE DETECTING DEVICES
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''DEF''
Class BClosed
Jan 13, 2026Apt 5E
CORRECT FAILURE TO INSTALL TEMPERATURE REPORTING DEVICE · HEAT SENSOR PROGRAM
§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''DEF''
Class BClosed
Jan 13, 2026
CORRECT FAILURE TO MAINTAIN R RECORDS REGARDING T DEVICES · HEAT SENSOR PROGRAM
§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. DATA REQUESTED FOR THE PERIOD OF OCTOBER 2025.
Class BClosed
Jan 13, 2026Apt 6F
CORRECT FAILURE TO INSTALL TEMPERATURE REPORTING DEVICE · HEAT SENSOR PROGRAM
§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH , SECTION ''DEF''
Class CClosed
Dec 3, 2025
PROVIDE ACCESS TO BOILER ROOM · HEAT AND HOT WATER
§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED BOILER ROOM AT BASEMENT
Class BOpen
Dec 2, 2025Apt 7A
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER WINDOW SASH AT EAST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class CClosedRENT IMPAIRING
Dec 2, 2025Apt 6D
INADEQUATE HEAT · HEAT AND HOT WATER
§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
Class BOpen
Dec 2, 2025Apt 7F
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE IN THE KITCHEN LOCATED AT APT 7F, 7th STORY, 1st APARTMENT FROM NORTH AT EAST
Class CClosedRENT IMPAIRING
Dec 2, 2025Apt 7F
INADEQUATE HOT WATER · HEAT AND HOT WATER
§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 7F, 7th STORY, 1st APARTMENT FROM NORTH AT EAST
Class COpenRENT IMPAIRING
Dec 2, 2025Apt 7F
INADEQUATE HEAT · HEAT AND HOT WATER
§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 7F, 7th STORY, 1st APARTMENT FROM NORTH AT EAST
Class BOpen
Dec 1, 2025Apt 7A
REPAIR · MAINTENANCE
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET DRAW AT EAST WALL IN THE KITCHEN LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BOpen
Dec 1, 2025Apt 7A
REPAIR OR REPLACE SMOKE DETECTOR · SMOKE DETECTING DEVICES
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BOpen
Dec 1, 2025Apt 7A
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 5th ROOM FROM NORTH AT WEST LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BOpen
Dec 1, 2025Apt 7A
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE AT BATHTUB IN THE BATHROOM LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH
Class BOpen
Dec 1, 2025Apt 7A
REPAIR WITH SIMILAR MATERIAL · MAINTENANCE
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 7A, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH